Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay)

ACEH; ACEII; ACE-II; Peptidyl-Dipeptidase A; ACE-related carboxypeptidase; Angiotensin-converting enzyme homolog; Metalloprotease MPROT15

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 86-94 91
EDTA plasma(n=5) 89-97 92
heparin plasma(n=5) 95-103 101

Precision of the Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-99% 98-105% 92-105% 80-103%
EDTA plasma(n=5) 91-101% 94-103% 80-98% 95-102%
heparin plasma(n=5) 81-90% 81-95% 82-89% 84-97%

Stability of the Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
EPB886Ra61 Eukaryotic Angiotensin I Converting Enzyme 2 (ACE2) Positive Control; Immunogen; SDS-PAGE; WB.
APB886Ra61 Active Angiotensin I Converting Enzyme 2 (ACE2) Cell culture; Activity Assays.
APB886Ra01 Active Angiotensin I Converting Enzyme 2 (ACE2) Cell culture; Activity Assays.
RPB886Ra01 Recombinant Angiotensin I Converting Enzyme 2 (ACE2) Positive Control; Immunogen; SDS-PAGE; WB.
PAB886Ra01 Polyclonal Antibody to Angiotensin I Converting Enzyme 2 (ACE2) WB; IHC; ICC; IP.
MAB886Ra23 Monoclonal Antibody to Angiotensin I Converting Enzyme 2 (ACE2) WB; IHC; ICC; IP.
MAB886Ra22 Monoclonal Antibody to Angiotensin I Converting Enzyme 2 (ACE2) WB; IHC; ICC; IP.
MAB886Ra24 Monoclonal Antibody to Angiotensin I Converting Enzyme 2 (ACE2) WB; IHC; ICC; IP.
MAB886Ra21 Monoclonal Antibody to Angiotensin I Converting Enzyme 2 (ACE2) WB; IHC; ICC; IP.
SEB886Ra ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB886Ra Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.