ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2)

ACEH; ACEII; ACE-II; Peptidyl-Dipeptidase A; ACE-related carboxypeptidase; Angiotensin-converting enzyme homolog; Metalloprotease MPROT15

  • ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2) Packages (Simulation)
  • ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2) Packages (Simulation)
  • ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2) Results demonstration
  • SEB886Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2)

This assay has high sensitivity and excellent specificity for detection of Angiotensin I Converting Enzyme 2 (ACE2).
No significant cross-reactivity or interference between Angiotensin I Converting Enzyme 2 (ACE2) and analogues was observed.

Recovery of the ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2)

Matrices listed below were spiked with certain level of recombinant Angiotensin I Converting Enzyme 2 (ACE2) and the recovery rates were calculated by comparing the measured value to the expected amount of Angiotensin I Converting Enzyme 2 (ACE2) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 79-93 80
heparin plasma(n=5) 78-95 86

Precision of the ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiotensin I Converting Enzyme 2 (ACE2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiotensin I Converting Enzyme 2 (ACE2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiotensin I Converting Enzyme 2 (ACE2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-92% 83-97% 80-95% 97-104%
EDTA plasma(n=5) 80-102% 91-101% 78-104% 83-105%
heparin plasma(n=5) 88-104% 85-92% 98-105% 78-101%

Stability of the ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Angiotensin I Converting Enzyme 2 (ACE2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Angiotensin I Converting Enzyme 2 (ACE2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Angiotensin I Converting Enzyme 2 (ACE2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Angiotensin I Converting Enzyme 2 (ACE2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
EPB886Ra61 Eukaryotic Angiotensin I Converting Enzyme 2 (ACE2) Positive Control; Immunogen; SDS-PAGE; WB.
APB886Ra61 Active Angiotensin I Converting Enzyme 2 (ACE2) Cell culture; Activity Assays.
APB886Ra01 Active Angiotensin I Converting Enzyme 2 (ACE2) Cell culture; Activity Assays.
RPB886Ra01 Recombinant Angiotensin I Converting Enzyme 2 (ACE2) Positive Control; Immunogen; SDS-PAGE; WB.
PAB886Ra01 Polyclonal Antibody to Angiotensin I Converting Enzyme 2 (ACE2) WB; IHC; ICC; IP.
MAB886Ra23 Monoclonal Antibody to Angiotensin I Converting Enzyme 2 (ACE2) WB; IHC; ICC; IP.
MAB886Ra22 Monoclonal Antibody to Angiotensin I Converting Enzyme 2 (ACE2) WB; IHC; ICC; IP.
MAB886Ra24 Monoclonal Antibody to Angiotensin I Converting Enzyme 2 (ACE2) WB; IHC; ICC; IP.
MAB886Ra21 Monoclonal Antibody to Angiotensin I Converting Enzyme 2 (ACE2) WB; IHC; ICC; IP.
SEB886Ra ELISA Kit for Angiotensin I Converting Enzyme 2 (ACE2) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB886Ra Multiplex Assay Kit for Angiotensin I Converting Enzyme 2 (ACE2) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK