Mini Samples ELISA Kit for Glucagon Like Peptide 1 (GLP1)
- Product No.MEA804Mi
- Organism SpeciesHomo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat), Oryctolagus cuniculus (Rabbit), Canis familiaris; Canine (Dog), Bos taurus; Bovine (Cattle) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range12.35-1,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 4.24pg/mL.
- Sample Typeserum, plasma and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 545
For more details, please contact local distributors!US$ 778
For more details, please contact local distributors! US$ 3501
For more details, please contact local distributors! US$ 6613
For more details, please contact local distributors! US$ 54460
For more details, please contact local distributors!
Specificity of the Mini Samples ELISA Kit for Glucagon Like Peptide 1 (GLP1)
This assay has high sensitivity for detection of Mini Samples Glucagon Like Peptide 1 (GLP1).
100% cross-reactivity of Mini Samples Glucagon Like Peptide 1 (GLP1) was observed among Human, Mouse, Rat, Rabbit, Canine, Bovine.
Recovery of the Mini Samples ELISA Kit for Glucagon Like Peptide 1 (GLP1)
Matrices listed below were spiked with certain level of recombinant Mini Samples Glucagon Like Peptide 1 (GLP1) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Glucagon Like Peptide 1 (GLP1) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-89 | 85 |
EDTA plasma(n=5) | 92-99 | 96 |
heparin plasma(n=5) | 79-102 | 97 |
Precision of the Mini Samples ELISA Kit for Glucagon Like Peptide 1 (GLP1)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Glucagon Like Peptide 1 (GLP1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Glucagon Like Peptide 1 (GLP1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Mini Samples ELISA Kit for Glucagon Like Peptide 1 (GLP1)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Glucagon Like Peptide 1 (GLP1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 86-101% | 88-95% | 86-94% | 92-99% |
EDTA plasma(n=5) | 89-97% | 79-101% | 80-95% | 80-90% |
heparin plasma(n=5) | 94-103% | 80-90% | 91-105% | 97-105% |
Stability of the Mini Samples ELISA Kit for Glucagon Like Peptide 1 (GLP1)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Mini Samples ELISA Kit for Glucagon Like Peptide 1 (GLP1)
1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well.
And then add 25μL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 50µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 50µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 25µL Stop Solution. Read at 450 nm immediately.
Test principle of the Mini Samples ELISA Kit for Glucagon Like Peptide 1 (GLP1)
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Mini Samples Glucagon Like Peptide 1 (GLP1) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Mini Samples Glucagon Like Peptide 1 (GLP1) and unlabeled Mini Samples Glucagon Like Peptide 1 (GLP1) (Standards or samples) with the pre-coated antibody specific to Mini Samples Glucagon Like Peptide 1 (GLP1). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Mini Samples Glucagon Like Peptide 1 (GLP1) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Mini Samples Glucagon Like Peptide 1 (GLP1) in the sample.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat), Oryctolagus cuniculus (Rabbit), Canis familiaris; Canine (Dog), Bos taurus; Bovine (Cattle) | Applications (RESEARCH USE ONLY!) |
CPA804Mi22 | OVA Conjugated Glucagon Like Peptide 1 (GLP1) | Immunogen; SDS-PAGE; WB. |
SPA804Mi01 | Synthetic Glucagon Like Peptide 1 (GLP1) | Immunogen; Blocking Peptide. |
CPA804Mi21 | OVA Conjugated Glucagon Like Peptide 1 (GLP1) | Immunogen; SDS-PAGE; WB. |
PAA804Mi01 | Polyclonal Antibody to Glucagon Like Peptide 1 (GLP1) | WB; IHC; ICC; IP. |
MAA804Mi21 | Monoclonal Antibody to Glucagon Like Peptide 1 (GLP1) | WB; IHC; ICC; IP. |
MAA804Mi22 | Monoclonal Antibody to Glucagon Like Peptide 1 (GLP1) | WB; IHC; ICC; IP. |
MAA804Mi24 | Monoclonal Antibody to Glucagon Like Peptide 1 (GLP1) | WB; IHC; ICC; IP. |
MEA804Mi | Mini Samples ELISA Kit for Glucagon Like Peptide 1 (GLP1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA804Mi | ELISA Kit for Glucagon Like Peptide 1 (GLP1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA804Mi | Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |