Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay)
(Note: Up to 8-plex in one testing reaction)
- Product No.LMA804Mi
- Organism SpeciesHomo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat), Oryctolagus cuniculus (Rabbit), Canis familiaris; Canine (Dog), Bos taurus; Bovine (Cattle) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.98-1000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 pg/mL.
- Sample TypeSerum, plasma and other biological fluids
- Download Instruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
-
FOB
US$ 405
For more details, please contact local distributors! US$ 420
For more details, please contact local distributors! US$ 443
For more details, please contact local distributors! US$ 475
For more details, please contact local distributors! US$ 506
For more details, please contact local distributors! US$ 552
For more details, please contact local distributors! US$ 622
For more details, please contact local distributors!US$ 778
For more details, please contact local distributors!
Specificity of the Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay)
This assay has high sensitivity for detection of Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay).
100% cross-reactivity of Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) was observed among Human, Mouse, Rat, Rabbit, Canine, Bovine.
Recovery of the Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay)
Matrices listed below were spiked with certain level of recombinant Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 91-101 | 98 |
EDTA plasma(n=5) | 84-93 | 89 |
heparin plasma(n=5) | 92-105 | 101 |
Precision of the Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-91% | 78-101% | 95-103% | 96-105% |
EDTA plasma(n=5) | 91-98% | 98-105% | 86-97% | 95-105% |
heparin plasma(n=5) | 93-101% | 98-105% | 78-101% | 91-98% |
Stability of the Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay)
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Test principle of the Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay)
Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Homo sapiens (Human), Mus musculus (Mouse), Rattus norvegicus (Rat), Oryctolagus cuniculus (Rabbit), Canis familiaris; Canine (Dog), Bos taurus; Bovine (Cattle) | Applications (RESEARCH USE ONLY!) |
CPA804Mi22 | OVA Conjugated Glucagon Like Peptide 1 (GLP1) | Immunogen; SDS-PAGE; WB. |
SPA804Mi01 | Synthetic Glucagon Like Peptide 1 (GLP1) | Immunogen; Blocking Peptide. |
CPA804Mi21 | OVA Conjugated Glucagon Like Peptide 1 (GLP1) | Immunogen; SDS-PAGE; WB. |
PAA804Mi01 | Polyclonal Antibody to Glucagon Like Peptide 1 (GLP1) | WB; IHC; ICC; IP. |
MAA804Mi21 | Monoclonal Antibody to Glucagon Like Peptide 1 (GLP1) | WB; IHC; ICC; IP. |
MAA804Mi22 | Monoclonal Antibody to Glucagon Like Peptide 1 (GLP1) | WB; IHC; ICC; IP. |
MAA804Mi24 | Monoclonal Antibody to Glucagon Like Peptide 1 (GLP1) | WB; IHC; ICC; IP. |
MEA804Mi | Mini Samples ELISA Kit for Glucagon Like Peptide 1 (GLP1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA804Mi | ELISA Kit for Glucagon Like Peptide 1 (GLP1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA804Mi | Multiplex Assay Kit for Glucagon Like Peptide 1 (GLP1) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |