Instant ELISA Kit for Melatonin (MT)
N-Acetyl-5-Methoxytryptamine
- Product No.IEA908Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length1h, 10min
- Detection Range6.17-500pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 2.51pg/mL.
- Sample Typeserum, plasma and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 669
For more details, please contact local distributors!US$ 955
For more details, please contact local distributors! US$ 4298
For more details, please contact local distributors! US$ 8118
For more details, please contact local distributors! US$ 66850
For more details, please contact local distributors!
Specificity of the Instant ELISA Kit for Melatonin (MT)
This assay has high sensitivity and excellent specificity for detection of Instant Melatonin (MT).
No significant cross-reactivity or interference between Instant Melatonin (MT) and analogues was observed.
Recovery of the Instant ELISA Kit for Melatonin (MT)
Matrices listed below were spiked with certain level of Instant Melatonin (MT) and the recovery rates were calculated by comparing the measured value to the expected amount of Instant Melatonin (MT) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-98 | 92 |
EDTA plasma(n=5) | 83-93 | 89 |
heparin plasma(n=5) | 88-102 | 98 |
Precision of the Instant ELISA Kit for Melatonin (MT)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Instant Melatonin (MT) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Instant Melatonin (MT) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Instant ELISA Kit for Melatonin (MT)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Instant Melatonin (MT) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-98% | 80-101% | 81-99% | 92-101% |
EDTA plasma(n=5) | 78-91% | 93-105% | 90-97% | 89-96% |
heparin plasma(n=5) | 93-102% | 86-105% | 80-96% | 80-101% |
Stability of the Instant ELISA Kit for Melatonin (MT)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Instant ELISA Kit for Melatonin (MT)
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Share and mix. Incubate 50 minutes at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 10 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the Instant ELISA Kit for Melatonin (MT)
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Instant Melatonin (MT) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Instant Melatonin (MT) and unlabeled Instant Melatonin (MT) (Standards or samples) with the pre-coated antibody specific to Instant Melatonin (MT). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Instant Melatonin (MT) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Instant Melatonin (MT) in the sample.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Pan-species (General) | Applications (RESEARCH USE ONLY!) |
CPA908Ge11 | BSA Conjugated Melatonin (MT) | Immunogen; SDS-PAGE; WB. |
CPA908Ge21 | OVA Conjugated Melatonin (MT) | Immunogen; SDS-PAGE; WB. |
PAA908Ge01 | Polyclonal Antibody to Melatonin (MT) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MEA908Ge | Mini Samples ELISA Kit for Melatonin (MT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA908Ge | ELISA Kit for Melatonin (MT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
HEA908Ge | High Sensitive ELISA Kit for Melatonin (MT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
IEA908Ge | Instant ELISA Kit for Melatonin (MT) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCA908Ge | CLIA Kit for Melatonin (MT) | Chemiluminescent immunoassay for Antigen Detection. |
LMA908Ge | Multiplex Assay Kit for Melatonin (MT) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA908Ge11 | ELISA Kit DIY Materials for Melatonin (MT) | Main materials for "Do It (ELISA Kit) Yourself". |