High Sensitive ELISA Kit for Malondialdehyde (MDA)

  • High Sensitive ELISA Kit for Malondialdehyde (MDA) Packages (Simulation)
  • High Sensitive ELISA Kit for Malondialdehyde (MDA) Packages (Simulation)
  • High Sensitive ELISA Kit for Malondialdehyde (MDA) Results demonstration
  • HEA597Ge.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the High Sensitive ELISA Kit for Malondialdehyde (MDA)

This assay has high sensitivity and excellent specificity for detection of High Sensitive Malondialdehyde (MDA).
No significant cross-reactivity or interference between High Sensitive Malondialdehyde (MDA) and analogues was observed.

Recovery of the High Sensitive ELISA Kit for Malondialdehyde (MDA)

Matrices listed below were spiked with certain level of High Sensitive Malondialdehyde (MDA) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Malondialdehyde (MDA) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-92 88
EDTA plasma(n=5) 91-99 95
heparin plasma(n=5) 81-95 86

Precision of the High Sensitive ELISA Kit for Malondialdehyde (MDA)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Malondialdehyde (MDA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Malondialdehyde (MDA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the High Sensitive ELISA Kit for Malondialdehyde (MDA)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Malondialdehyde (MDA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 80-95% 95-105% 80-95% 96-103%
EDTA plasma(n=5) 79-92% 92-99% 84-95% 90-104%
heparin plasma(n=5) 78-92% 97-104% 78-92% 94-101%

Stability of the High Sensitive ELISA Kit for Malondialdehyde (MDA)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the High Sensitive ELISA Kit for Malondialdehyde (MDA)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.

Test principle of the High Sensitive ELISA Kit for Malondialdehyde (MDA)

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to High Sensitive Malondialdehyde (MDA) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled High Sensitive Malondialdehyde (MDA) and unlabeled High Sensitive Malondialdehyde (MDA) (Standards or samples) with the pre-coated antibody specific to High Sensitive Malondialdehyde (MDA). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of High Sensitive Malondialdehyde (MDA) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of High Sensitive Malondialdehyde (MDA) in the sample.

Related products

Catalog No. Organism species: Pan-species (General) Applications (RESEARCH USE ONLY!)
UCPA597Ge41 HSA Conjugated Malondialdehyde (MDA) Immunogen; SDS-PAGE; WB.
UCPA597Ge11 BSA Conjugated Malondialdehyde (MDA) Immunogen; SDS-PAGE; WB.
UCPA597Ge21 OVA Conjugated Malondialdehyde (MDA) Immunogen; SDS-PAGE; WB.
UPAA597Ge01 Polyclonal Antibody to Malondialdehyde (MDA) ELISA
UMAA597Ge24 Monoclonal Antibody to Malondialdehyde (MDA) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
UMAA597Ge23 Monoclonal Antibody to Malondialdehyde (MDA) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
UMAA597Ge22 Monoclonal Antibody to Malondialdehyde (MDA) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
UMAA597Ge21 Monoclonal Antibody to Malondialdehyde (MDA) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
UCEA597Ge ELISA Kit for Malondialdehyde (MDA) Enzyme-linked immunosorbent assay for Antigen Detection.
UHEA597Ge High Sensitive ELISA Kit for Malondialdehyde (MDA) Enzyme-linked immunosorbent assay for Antigen Detection.
UMEA597Ge Mini Samples ELISA Kit for Malondialdehyde (MDA) Enzyme-linked immunosorbent assay for Antigen Detection.
ULMA597Ge Multiplex Assay Kit for Malondialdehyde (MDA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UKSA597Ge11 ELISA Kit DIY Materials for Malondialdehyde (MDA) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK