ELISA Kit for Neurofilament, Light Polypeptide (NEFL)

CMT1F; CMT2E; NF-L; NF68; NFL; 68 kDa neurofilament protein; Neurofilament triplet L protein

  • ELISA Kit for Neurofilament, Light Polypeptide (NEFL) Packages (Simulation)
  • ELISA Kit for Neurofilament, Light Polypeptide (NEFL) Packages (Simulation)
  • ELISA Kit for Neurofilament, Light Polypeptide (NEFL) Results demonstration
  • CEE038Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Neurofilament, Light Polypeptide (NEFL)

This assay has high sensitivity and excellent specificity for detection of Neurofilament, Light Polypeptide (NEFL).
No significant cross-reactivity or interference between Neurofilament, Light Polypeptide (NEFL) and analogues was observed.

Recovery of the ELISA Kit for Neurofilament, Light Polypeptide (NEFL)

Matrices listed below were spiked with certain level of recombinant Neurofilament, Light Polypeptide (NEFL) and the recovery rates were calculated by comparing the measured value to the expected amount of Neurofilament, Light Polypeptide (NEFL) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 84-98 93
EDTA plasma(n=5) 81-104 88
heparin plasma(n=5) 98-105 101

Precision of the ELISA Kit for Neurofilament, Light Polypeptide (NEFL)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Neurofilament, Light Polypeptide (NEFL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Neurofilament, Light Polypeptide (NEFL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Neurofilament, Light Polypeptide (NEFL)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Neurofilament, Light Polypeptide (NEFL) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-101% 80-94% 95-103% 88-95%
EDTA plasma(n=5) 91-105% 80-104% 95-105% 80-99%
heparin plasma(n=5) 79-94% 79-101% 85-104% 94-102%

Stability of the ELISA Kit for Neurofilament, Light Polypeptide (NEFL)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Neurofilament, Light Polypeptide (NEFL)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.

Test principle of the ELISA Kit for Neurofilament, Light Polypeptide (NEFL)

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Neurofilament, Light Polypeptide (NEFL) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Neurofilament, Light Polypeptide (NEFL) and unlabeled Neurofilament, Light Polypeptide (NEFL) (Standards or samples) with the pre-coated antibody specific to Neurofilament, Light Polypeptide (NEFL). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Neurofilament, Light Polypeptide (NEFL) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Neurofilament, Light Polypeptide (NEFL) in the sample.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
URPE038Hu03 Recombinant Neurofilament, Light Polypeptide (NEFL) Positive Control; Immunogen; SDS-PAGE; WB.
URPE038Hu02 Recombinant Neurofilament, Light Polypeptide (NEFL) Positive Control; Immunogen; SDS-PAGE; WB.
URPE038Hu01 Recombinant Neurofilament, Light Polypeptide (NEFL) Positive Control; Immunogen; SDS-PAGE; WB.
UCPE038Hu21 OVA Conjugated Neurofilament, Light Polypeptide (NEFL) Immunogen; SDS-PAGE; WB.
UPAE038Hu08 Polyclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
UPAE038Hu02 Polyclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
UPAE038Hu01 Polyclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
ULAE038Hu71 Biotin-Linked Polyclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC.
UMAE038Hu25 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
UMAE038Hu27 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
UMAE038Hu23 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
UMAE038Hu22 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
UMAE038Hu21 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC
UMAE038Hu24 Monoclonal Antibody to Neurofilament, Light Polypeptide (NEFL) WB; IHC; ICC; IP.
UFAE038Hu08 Anti-Neurofilament, Light Polypeptide (NEFL) Monoclonal Antibody Flow cytometry.
UFAE038Hu02 Anti-Neurofilament, Light Polypeptide (NEFL) Monoclonal Antibody Flow cytometry.
UFAE038Hu06 Anti-Neurofilament, Light Polypeptide (NEFL) Monoclonal Antibody Flow cytometry.
UFAE038Hu04 Anti-Neurofilament, Light Polypeptide (NEFL) Monoclonal Antibody Flow cytometry.
USEE038Hu ELISA Kit for Neurofilament, Light Polypeptide (NEFL) Enzyme-linked immunosorbent assay for Antigen Detection.
UHEE038Hu High Sensitive ELISA Kit for Neurofilament, Light Polypeptide (NEFL) Enzyme-linked immunosorbent assay for Antigen Detection.
UMEE038Hu Mini Samples ELISA Kit for Neurofilament, Light Polypeptide (NEFL) Enzyme-linked immunosorbent assay for Antigen Detection.
UCEE038Hu ELISA Kit for Neurofilament, Light Polypeptide (NEFL) Enzyme-linked immunosorbent assay for Antigen Detection.
USCE038Hu CLIA Kit for Neurofilament, Light Polypeptide (NEFL) Chemiluminescent immunoassay for Antigen Detection.
ULME038Hu Multiplex Assay Kit for Neurofilament, Light Polypeptide (NEFL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UKSE038Hu01 ELISA Kit DIY Materials for Neurofilament, Light Polypeptide (NEFL) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK