ELISA Kit for Interleukin 8 (IL8)
CXCL8; AMCF-I; GCP1; K60; LECT; LUCT; LYNAP; MDNCF; MONAP; NAF; NAP1; SCYB8; TSG1; B-ENAP; Neutrophil-Activating Protein 1; Granulocyte Chemotactic Protein 1
- Product No.SEA080Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range15.6-1,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 6.0pg/mL.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 349
For more details, please contact local distributors!US$ 498
For more details, please contact local distributors! US$ 2241
For more details, please contact local distributors! US$ 4233
For more details, please contact local distributors! US$ 34860
For more details, please contact local distributors!
Specificity of the ELISA Kit for Interleukin 8 (IL8)
This assay has high sensitivity and excellent specificity for detection of Interleukin 8 (IL8).
No significant cross-reactivity or interference between Interleukin 8 (IL8) and analogues was observed.
Recovery of the ELISA Kit for Interleukin 8 (IL8)
Matrices listed below were spiked with certain level of recombinant Interleukin 8 (IL8) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 8 (IL8) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 88-102 | 96 |
EDTA plasma(n=5) | 79-91 | 87 |
heparin plasma(n=5) | 97-104 | 101 |
Precision of the ELISA Kit for Interleukin 8 (IL8)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 8 (IL8) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 8 (IL8) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the ELISA Kit for Interleukin 8 (IL8)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 8 (IL8) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 91-101% | 79-93% | 97-105% | 95-103% |
EDTA plasma(n=5) | 93-101% | 86-103% | 80-91% | 82-103% |
heparin plasma(n=5) | 80-101% | 81-93% | 78-93% | 96-105% |
Stability of the ELISA Kit for Interleukin 8 (IL8)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the ELISA Kit for Interleukin 8 (IL8)
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the ELISA Kit for Interleukin 8 (IL8)
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Interleukin 8 (IL8). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Interleukin 8 (IL8). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Interleukin 8 (IL8), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Interleukin 8 (IL8) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
INCREMENT SERVICES
Single-component Reagents of Assay Kit
Lysis Buffer Specific for ELISA / CLIA
Quality Control of Kit
ELISA Kit Customized Service
Disease Model Customized Service
Serums Customized Service
TGFB1 Activation Reagent
Real Time PCR Experimental Service
Streptavidin
Fast blue Protein Stain solution
Single-component Reagents of FLIA Kit
Streptavidin-Agarose Beads
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
APA080Hu01 | Active Interleukin 8 (IL8) | Cell culture; Activity Assays. |
RPA080Hu01 | Recombinant Interleukin 8 (IL8) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA080Hu01 | Polyclonal Antibody to Interleukin 8 (IL8) | WB; IHC; ICC; IP. |
LAA080Hu71 | Biotin-Linked Polyclonal Antibody to Interleukin 8 (IL8) | WB; IHC; ICC. |
LAA080Hu81 | FITC-Linked Polyclonal Antibody to Interleukin 8 (IL8) | WB; IHC; ICC; IF. |
MAA080Hu24 | Monoclonal Antibody to Interleukin 8 (IL8) | WB; IHC; ICC; IP. |
MAA080Hu21 | Monoclonal Antibody to Interleukin 8 (IL8) | WB; IHC; ICC; IP. |
MAA080Hu22 | Monoclonal Antibody to Interleukin 8 (IL8) | WB; IHC; ICC; IP. |
LAA080Hu82 | FITC-Linked Monoclonal Antibody to Interleukin 8 (IL8) | WB; IHC; ICC; IF. |
LAA080Hu72 | Biotin-Linked Monoclonal Antibody to Interleukin 8 (IL8) | WB; IHC; ICC. |
FAA080Hu22 | Labelled Anti-Interleukin 8 (IL8) Monoclonal Antibody | FCM |
MEA080Hu | Mini Samples ELISA Kit for Interleukin 8 (IL8) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SEA080Hu | ELISA Kit for Interleukin 8 (IL8) | Enzyme-linked immunosorbent assay for Antigen Detection. |
HEA080Hu | High Sensitive ELISA Kit for Interleukin 8 (IL8) | Enzyme-linked immunosorbent assay for Antigen Detection. |
IEA080Hu | Instant ELISA Kit for Interleukin 8 (IL8) | Enzyme-linked immunosorbent assay for Antigen Detection. |
AEA080Hu | ELISA Kit for Anti-Interleukin 8 Antibody (Anti-IL8) | Enzyme-linked immunosorbent assay for Antibody Detection. |
SCA080Hu | CLIA Kit for Interleukin 8 (IL8) | Chemiluminescent immunoassay for Antigen Detection. |
LMA080Hu | Multiplex Assay Kit for Interleukin 8 (IL8) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
PSA080Hu01 | Antibody Pair for Interleukin 8 (IL8) | ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays. |
KSA080Hu01 | ELISA Kit DIY Materials for Interleukin 8 (IL8) | Main materials for "Do It (ELISA Kit) Yourself". |