CLIA Kit for Phospholipase A2 Group VII (LpPLA2)
PLA2G7; PAF-AH; PAFAH; Lp-PLA2; LDL-PLA2; Platelet Activating Factor Acetylhydrolase,Plasma; Phospholipase A2,Group VII; LDL-associated phospholipase A2; Phospholipase A2, Lipoprotein Associated
- Product No.USCA867Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length2h, 40min
- Detection Range13.7-10,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 4.8pg/mL.
- Sample TypeSerum, plasma and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
- 
    FOB
    
                        US$ 294 
 For more details, please contact local distributors!US$ 420
 For more details, please contact local distributors! US$ 1890
 For more details, please contact local distributors! US$ 3570
 For more details, please contact local distributors! US$ 29400
 For more details, please contact local distributors!
Specificity of the CLIA Kit for Phospholipase A2 Group VII (LpPLA2)
                        This assay has high sensitivity and excellent specificity for detection of Phospholipase A2 Group VII (LpPLA2).
                        No significant cross-reactivity or interference between Phospholipase A2 Group VII (LpPLA2) and analogues was observed.
                    
Recovery of the CLIA Kit for Phospholipase A2 Group VII (LpPLA2)
Matrices listed below were spiked with certain level of recombinant Phospholipase A2 Group VII (LpPLA2) and the recovery rates were calculated by comparing the measured value to the expected amount of Phospholipase A2 Group VII (LpPLA2) in samples.
| Matrix | Recovery range (%) | Average(%) | 
| serum(n=5) | 79-104 | 91 | 
| EDTA plasma(n=5) | 95-102 | 99 | 
| heparin plasma(n=5) | 85-105 | 94 | 
Precision of the CLIA Kit for Phospholipase A2 Group VII (LpPLA2)
                    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Phospholipase A2 Group VII (LpPLA2) were tested 20 times on one plate, respectively. 
                    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Phospholipase A2 Group VII (LpPLA2) were tested on 3 different plates, 8 replicates in each plate. 
                    CV(%) = SD/meanX100 
                    Intra-Assay: CV<10% 
                    Inter-Assay: CV<12% 
                
Linearity of the CLIA Kit for Phospholipase A2 Group VII (LpPLA2)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Phospholipase A2 Group VII (LpPLA2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 | 
| serum(n=5) | 86-94% | 78-95% | 91-105% | 81-92% | 
| EDTA plasma(n=5) | 78-92% | 80-95% | 98-105% | 90-104% | 
| heparin plasma(n=5) | 87-94% | 90-104% | 92-101% | 79-90% | 
Stability of the CLIA Kit for Phospholipase A2 Group VII (LpPLA2)
                    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. 
                    To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
                
Assay procedure summary of the CLIA Kit for Phospholipase A2 Group VII (LpPLA2)
                    1. Prepare all reagents, samples and standards;
                            2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
                            3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
                            4. Aspirate and wash 3 times;
                            5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
                            6. Aspirate and wash 5 times;
                            7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
                            8. Read RLU value immediately.
                
Test principle of the CLIA Kit for Phospholipase A2 Group VII (LpPLA2)
The microplate provided in this kit has been pre-coated with an antibody specific to Phospholipase A2 Group VII (LpPLA2). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Phospholipase A2 Group VII (LpPLA2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Phospholipase A2 Group VII (LpPLA2) level in the sample or standard.;
GIVEAWAYS
INCREMENT SERVICES
                    Single-component Reagents of Assay Kit
                            Lysis Buffer Specific for ELISA / CLIA
                            Quality Control of Kit
                            CLIA Kit Customized Service
                            Disease Model Customized Service
                            Serums Customized Service
                            TGFB1 Activation Reagent
                            Real Time PCR Experimental Service
                            Streptavidin
                            Fast blue Protein Stain solution
                            Single-component Reagents of FLIA Kit
                            Streptavidin-Agarose Beads
                                            

 
                     
                    