Mini Samples ELISA Kit for Myeloperoxidase (MPO)

  • Mini Samples ELISA Kit for Myeloperoxidase (MPO) Packages (Simulation)
  • Mini Samples ELISA Kit for Myeloperoxidase (MPO) Packages (Simulation)
  • Mini Samples ELISA Kit for Myeloperoxidase (MPO) Results demonstration
  • MEA601Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Mini Samples ELISA Kit for Myeloperoxidase (MPO)

This assay has high sensitivity and excellent specificity for detection of Mini Samples Myeloperoxidase (MPO).
No significant cross-reactivity or interference between Mini Samples Myeloperoxidase (MPO) and analogues was observed.

Recovery of the Mini Samples ELISA Kit for Myeloperoxidase (MPO)

Matrices listed below were spiked with certain level of recombinant Mini Samples Myeloperoxidase (MPO) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Myeloperoxidase (MPO) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-96 92
EDTA plasma(n=5) 79-102 83
heparin plasma(n=5) 79-104 89

Precision of the Mini Samples ELISA Kit for Myeloperoxidase (MPO)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Myeloperoxidase (MPO) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Myeloperoxidase (MPO) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Mini Samples ELISA Kit for Myeloperoxidase (MPO)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Myeloperoxidase (MPO) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-98% 92-101% 80-102% 86-101%
EDTA plasma(n=5) 86-94% 89-102% 96-105% 88-96%
heparin plasma(n=5) 79-93% 89-98% 80-99% 93-104%

Stability of the Mini Samples ELISA Kit for Myeloperoxidase (MPO)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Mini Samples ELISA Kit for Myeloperoxidase (MPO)

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.

Test principle of the Mini Samples ELISA Kit for Myeloperoxidase (MPO)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mini Samples Myeloperoxidase (MPO). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mini Samples Myeloperoxidase (MPO). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mini Samples Myeloperoxidase (MPO), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mini Samples Myeloperoxidase (MPO) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
RPA601Ra01 Recombinant Myeloperoxidase (MPO) Positive Control; Immunogen; SDS-PAGE; WB.
RPA601Ra02 Recombinant Myeloperoxidase (MPO) Positive Control; Immunogen; SDS-PAGE; WB.
PAA601Ra02 Polyclonal Antibody to Myeloperoxidase (MPO) WB; IHC; ICC; IP.
PAA601Ra01 Polyclonal Antibody to Myeloperoxidase (MPO) WB; IHC; ICC; IP.
MAA601Ra21 Monoclonal Antibody to Myeloperoxidase (MPO) WB; IHC; ICC; IP.
MEA601Ra Mini Samples ELISA Kit for Myeloperoxidase (MPO) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA601Ra ELISA Kit for Myeloperoxidase (MPO) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA601Ra CLIA Kit for Myeloperoxidase (MPO) Chemiluminescent immunoassay for Antigen Detection.
LMA601Ra Multiplex Assay Kit for Myeloperoxidase (MPO) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK