Multiplex Assay Kit for Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay)

3,3',5-Triiodo-L-Thyronine; Liothyronine; Cytomel; Tertroxin

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-92 83
EDTA plasma(n=5) 85-95 90
heparin plasma(n=5) 83-91 87

Precision of the Multiplex Assay Kit for Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-93% 80-96% 97-105% 88-96%
EDTA plasma(n=5) 98-105% 93-102% 80-102% 78-102%
heparin plasma(n=5) 93-105% 95-104% 89-97% 91-99%

Stability of the Multiplex Assay Kit for Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

INCREMENT SERVICES

Related products

Catalog No. Organism species: Pan-species (General) Applications (RESEARCH USE ONLY!)
CPA453Ge11 BSA Conjugated Triiodothyronine (T3) Immunogen; SDS-PAGE; WB.
CPA453Ge21 OVA Conjugated Triiodothyronine (T3) Immunogen; SDS-PAGE; WB.
PAA453Ge01 Polyclonal Antibody to Triiodothyronine (T3) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
LAA453Ge71 Biotin-Linked Polyclonal Antibody to Triiodothyronine (T3) WB; IHC; ICC.
MAA453Ge21 Monoclonal Antibody to Triiodothyronine (T3) WB; IHC; ICC; IP.
MAA453Ge23 Monoclonal Antibody to Triiodothyronine (T3) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA453Ge22 Monoclonal Antibody to Triiodothyronine (T3) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA453Ge24 Monoclonal Antibody to Triiodothyronine (T3) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA453Ge25 Monoclonal Antibody to Triiodothyronine (T3) ELISA, CLIA. / IHC-Fr, ICC, IP (predicted).
MAA453Ge27 Monoclonal Antibody to Triiodothyronine (T3) WB; IHC; ICC; IP.
LAA453Ge72 Biotin-Linked Monoclonal Antibody to Triiodothyronine (T3) WB; IHC; ICC.
CEA453Ge ELISA Kit for Triiodothyronine (T3) Enzyme-linked immunosorbent assay for Antigen Detection.
IEA453Ge Instant ELISA Kit for Triiodothyronine (T3) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA453Ge Mini Samples ELISA Kit for Triiodothyronine (T3) Enzyme-linked immunosorbent assay for Antigen Detection.
AEA453Ge ELISA Kit for Anti-Triiodothyronine Antibody (Anti-T3) Enzyme-linked immunosorbent assay for Antibody Detection.
CCA453Ge CLIA Kit for Triiodothyronine (T3) Chemiluminescent immunoassay for Antigen Detection.
LMA453Ge Multiplex Assay Kit for Triiodothyronine (T3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA453Ge11 ELISA Kit DIY Materials for Triiodothyronine (T3) Main materials for "Do It (ELISA Kit) Yourself".