Multiplex Assay Kit for Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

CD227; EMA; H23AG; KL-6; PEM; PEMT; PUM; CA15-3; CA153; Cancer antigen 15-3; Carcinoma-associated mucin; Episialin; Peanut-reactive urinary mucin; Polymorphic epithelial mucin

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Precision of the Multiplex Assay Kit for Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Stability of the Multiplex Assay Kit for Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA413Hu01 Recombinant Mucin 1 (MUC1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA413Hu02 Recombinant Mucin 1 (MUC1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA413Hu03 Recombinant Mucin 1 (MUC1) Positive Control; Immunogen; SDS-PAGE; WB.
CPA413Hu21 OVA Conjugated Mucin 1 (MUC1) Immunogen; SDS-PAGE; WB.
SPA413Hu02 Synthetic Mucin 1 (MUC1) Immunogen; Blocking Peptide.
PAA413Hu01 Polyclonal Antibody to Mucin 1 (MUC1) WB; IHC; ICC; IP.
PAA413Hu08 Polyclonal Antibody to Mucin 1 (MUC1) WB; IHC; ICC; IP.
PAA413Hu02 Polyclonal Antibody to Mucin 1 (MUC1) WB; IHC; ICC; IP.
PAA413Hu03 Polyclonal Antibody to Mucin 1 (MUC1) WB; IHC; ICC; IP.
LAA413Hu81 FITC-Linked Polyclonal Antibody to Mucin 1 (MUC1) WB; IHC; ICC; IF.
LAA413Hu71 Biotin-Linked Polyclonal Antibody to Mucin 1 (MUC1) WB; IHC; ICC.
RAA413Hu21 Recombinant Antibody to Mucin 1 (MUC1) WB; IF; ICC; IHC; IP; FCM.
MAA413Hu22 Monoclonal Antibody to Mucin 1 (MUC1) WB
SEA413Hu ELISA Kit for Mucin 1 (MUC1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA413Hu CLIA Kit for Mucin 1 (MUC1) Chemiluminescent immunoassay for Antigen Detection.
LMA413Hu Multiplex Assay Kit for Mucin 1 (MUC1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA413Hu01 ELISA Kit DIY Materials for Mucin 1 (MUC1) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK