Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay)

DV27; C9ORF26; IL1F11; NFHEV; Interleukin-1 Family, Member 11; Nuclear factor from high endothelial venules

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 87-94 90
EDTA plasma(n=5) 96-105 101
heparin plasma(n=5) 97-104 101

Precision of the Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-105% 81-101% 79-91% 78-101%
EDTA plasma(n=5) 82-96% 93-105% 78-101% 94-105%
heparin plasma(n=5) 92-101% 98-105% 91-105% 78-96%

Stability of the Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPB980Hu02 Recombinant Interleukin 33 (IL33) Positive Control; Immunogen; SDS-PAGE; WB.
APB980Hu01 Active Interleukin 33 (IL33) Cell culture; Activity Assays.
RPB980Hu01 Recombinant Interleukin 33 (IL33) Positive Control; Immunogen; SDS-PAGE; WB.
PAB980Hu02 Polyclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC; IP.
PAB980Hu01 Polyclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC; IP.
LAB980Hu71 Biotin-Linked Polyclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC.
RAB980Hu21 Recombinant Antibody to Interleukin 33 (IL33) WB; IF; ICC; IHC; IP; FCM.
MAB980Hu24 Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC; IP.
MAB980Hu26 Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC; IP.
MAB980Hu21 Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC; IP.
MAB980Hu22 Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC
LAB980Hu72 Biotin-Linked Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC.
LAB980Hu76 Biotin-Linked Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC.
SEB980Hu ELISA Kit for Interleukin 33 (IL33) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB980Hu CLIA Kit for Interleukin 33 (IL33) Chemiluminescent immunoassay for Antigen Detection.
LMB980Hu Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSB980Hu01 Antibody Pair for Interleukin 33 (IL33) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSB980Hu01 ELISA Kit DIY Materials for Interleukin 33 (IL33) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK