CLIA Kit for Interleukin 33 (IL33)

DV27; C9ORF26; IL1F11; NFHEV; Interleukin-1 Family, Member 11; Nuclear factor from high endothelial venules

  • CLIA Kit for Interleukin 33 (IL33) Packages (Simulation)
  • CLIA Kit for Interleukin 33 (IL33) Packages (Simulation)
  • CLIA Kit for Interleukin 33 (IL33) Results demonstration
  • SCB980Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Interleukin 33 (IL33)

This assay has high sensitivity and excellent specificity for detection of Interleukin 33 (IL33).
No significant cross-reactivity or interference between Interleukin 33 (IL33) and analogues was observed.

Recovery of the CLIA Kit for Interleukin 33 (IL33)

Matrices listed below were spiked with certain level of recombinant Interleukin 33 (IL33) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 33 (IL33) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-105 102
EDTA plasma(n=5) 85-104 95
heparin plasma(n=5) 98-105 102

Precision of the CLIA Kit for Interleukin 33 (IL33)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 33 (IL33) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 33 (IL33) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Interleukin 33 (IL33)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 33 (IL33) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-101% 90-104% 88-101% 80-104%
EDTA plasma(n=5) 88-95% 84-101% 88-101% 78-105%
heparin plasma(n=5) 82-96% 97-104% 81-97% 98-105%

Stability of the CLIA Kit for Interleukin 33 (IL33)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Interleukin 33 (IL33)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Interleukin 33 (IL33)

The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 33 (IL33). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 33 (IL33). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 33 (IL33) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPB980Hu02 Recombinant Interleukin 33 (IL33) Positive Control; Immunogen; SDS-PAGE; WB.
APB980Hu01 Active Interleukin 33 (IL33) Cell culture; Activity Assays.
RPB980Hu01 Recombinant Interleukin 33 (IL33) Positive Control; Immunogen; SDS-PAGE; WB.
PAB980Hu02 Polyclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC; IP.
PAB980Hu01 Polyclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC; IP.
LAB980Hu71 Biotin-Linked Polyclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC.
RAB980Hu21 Recombinant Antibody to Interleukin 33 (IL33) WB; IF; ICC; IHC; IP; FCM.
MAB980Hu24 Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC; IP.
MAB980Hu26 Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC; IP.
MAB980Hu21 Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC; IP.
MAB980Hu22 Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC
LAB980Hu72 Biotin-Linked Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC.
LAB980Hu76 Biotin-Linked Monoclonal Antibody to Interleukin 33 (IL33) WB; IHC; ICC.
SEB980Hu ELISA Kit for Interleukin 33 (IL33) Enzyme-linked immunosorbent assay for Antigen Detection.
SCB980Hu CLIA Kit for Interleukin 33 (IL33) Chemiluminescent immunoassay for Antigen Detection.
LMB980Hu Multiplex Assay Kit for Interleukin 33 (IL33) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.