Multiplex Assay Kit for Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay)

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 79-104 91
EDTA plasma(n=5) 82-97 88
heparin plasma(n=5) 81-98 94

Precision of the Multiplex Assay Kit for Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 81-102% 79-96% 79-91%
EDTA plasma(n=5) 90-99% 90-104% 91-101% 94-105%
heparin plasma(n=5) 93-103% 82-99% 94-102% 80-103%

Stability of the Multiplex Assay Kit for Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
    add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
NPA448Ra01 Native Insulin (INS) Positive Control; Immunogen; SDS-PAGE; WB.
RPA448Ra01 Recombinant Insulin (INS) Positive Control; Immunogen; SDS-PAGE; WB.
PAA448Ra01 Polyclonal Antibody to Insulin (INS) WB; IHC; ICC; IP.
MAA448Ra21 Monoclonal Antibody to Insulin (INS) WB; IHC; ICC; IP.
CEA448Ra ELISA Kit for Insulin (INS) Enzyme-linked immunosorbent assay for Antigen Detection.
MEA448Ra Mini Samples ELISA Kit for Insulin (INS) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA448Ra High Sensitive ELISA Kit for Insulin (INS) Enzyme-linked immunosorbent assay for Antigen Detection.
CCA448Ra CLIA Kit for Insulin (INS) Chemiluminescent immunoassay for Antigen Detection.
LMA448Ra Multiplex Assay Kit for Insulin (INS) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA448Ra11 ELISA Kit DIY Materials for Insulin (INS) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK