CLIA Kit for Interleukin 8 (IL8)

CXCL8; AMCF-I; GCP1; K60; LECT; LUCT; LYNAP; MDNCF; MONAP; NAF; NAP1; SCYB8; TSG1; B-ENAP; Neutrophil-Activating Protein 1; Granulocyte Chemotactic Protein 1

  • CLIA Kit for Interleukin 8 (IL8) Packages (Simulation)
  • CLIA Kit for Interleukin 8 (IL8) Packages (Simulation)
  • CLIA Kit for Interleukin 8 (IL8) Results demonstration
  • SCA080Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Interleukin 8 (IL8)

This assay has high sensitivity and excellent specificity for detection of Interleukin 8 (IL8).
No significant cross-reactivity or interference between Interleukin 8 (IL8) and analogues was observed.

Recovery of the CLIA Kit for Interleukin 8 (IL8)

Matrices listed below were spiked with certain level of recombinant Interleukin 8 (IL8) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 8 (IL8) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-103 94
EDTA plasma(n=5) 95-105 102
heparin plasma(n=5) 79-97 93

Precision of the CLIA Kit for Interleukin 8 (IL8)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 8 (IL8) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 8 (IL8) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Interleukin 8 (IL8)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 8 (IL8) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 90-98% 82-92% 80-104% 98-105%
EDTA plasma(n=5) 86-94% 90-102% 88-104% 88-102%
heparin plasma(n=5) 94-101% 96-105% 79-88% 85-101%

Stability of the CLIA Kit for Interleukin 8 (IL8)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Interleukin 8 (IL8)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Interleukin 8 (IL8)

The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 8 (IL8). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 8 (IL8). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 8 (IL8) level in the sample or standard.;

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APA080Hu01 Active Interleukin 8 (IL8) Cell culture; Activity Assays.
RPA080Hu01 Recombinant Interleukin 8 (IL8) Positive Control; Immunogen; SDS-PAGE; WB.
PAA080Hu01 Polyclonal Antibody to Interleukin 8 (IL8) WB; IHC; ICC; IP.
LAA080Hu71 Biotin-Linked Polyclonal Antibody to Interleukin 8 (IL8) WB; IHC; ICC.
LAA080Hu81 FITC-Linked Polyclonal Antibody to Interleukin 8 (IL8) WB; IHC; ICC; IF.
MAA080Hu24 Monoclonal Antibody to Interleukin 8 (IL8) WB; IHC; ICC; IP.
MAA080Hu21 Monoclonal Antibody to Interleukin 8 (IL8) WB; IHC; ICC; IP.
MAA080Hu22 Monoclonal Antibody to Interleukin 8 (IL8) WB; IHC; ICC; IP.
LAA080Hu82 FITC-Linked Monoclonal Antibody to Interleukin 8 (IL8) WB; IHC; ICC; IF.
LAA080Hu72 Biotin-Linked Monoclonal Antibody to Interleukin 8 (IL8) WB; IHC; ICC.
FAA080Hu22 Labelled Anti-Interleukin 8 (IL8) Monoclonal Antibody FCM
MEA080Hu Mini Samples ELISA Kit for Interleukin 8 (IL8) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA080Hu ELISA Kit for Interleukin 8 (IL8) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA080Hu High Sensitive ELISA Kit for Interleukin 8 (IL8) Enzyme-linked immunosorbent assay for Antigen Detection.
IEA080Hu Instant ELISA Kit for Interleukin 8 (IL8) Enzyme-linked immunosorbent assay for Antigen Detection.
AEA080Hu ELISA Kit for Anti-Interleukin 8 Antibody (Anti-IL8) Enzyme-linked immunosorbent assay for Antibody Detection.
SCA080Hu CLIA Kit for Interleukin 8 (IL8) Chemiluminescent immunoassay for Antigen Detection.
LMA080Hu Multiplex Assay Kit for Interleukin 8 (IL8) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
PSA080Hu01 Antibody Pair for Interleukin 8 (IL8) ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
KSA080Hu01 ELISA Kit DIY Materials for Interleukin 8 (IL8) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK