Wide-range ELISA Kit for Salusin Beta (SALb)

  • Wide-range ELISA Kit for Salusin Beta (SALb) Packages (Simulation)
  • Wide-range ELISA Kit for Salusin Beta (SALb) Packages (Simulation)
  • Wide-range ELISA Kit for Salusin Beta (SALb) Results demonstration
  • WEC026Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Wide-range ELISA Kit for Salusin Beta (SALb)

This assay has high sensitivity and excellent specificity for detection of Wide-range Salusin Beta (SALb).
No significant cross-reactivity or interference between Wide-range Salusin Beta (SALb) and analogues was observed.

Recovery of the Wide-range ELISA Kit for Salusin Beta (SALb)

Matrices listed below were spiked with certain level of recombinant Wide-range Salusin Beta (SALb) and the recovery rates were calculated by comparing the measured value to the expected amount of Wide-range Salusin Beta (SALb) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-98 93
EDTA plasma(n=5) 88-101 96
heparin plasma(n=5) 79-92 88

Precision of the Wide-range ELISA Kit for Salusin Beta (SALb)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Wide-range Salusin Beta (SALb) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Wide-range Salusin Beta (SALb) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Wide-range ELISA Kit for Salusin Beta (SALb)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Wide-range Salusin Beta (SALb) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-104% 95-105% 80-95% 86-94%
EDTA plasma(n=5) 83-101% 78-102% 91-98% 92-101%
heparin plasma(n=5) 78-93% 79-90% 78-97% 89-98%

Stability of the Wide-range ELISA Kit for Salusin Beta (SALb)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Wide-range ELISA Kit for Salusin Beta (SALb)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.

Test principle of the Wide-range ELISA Kit for Salusin Beta (SALb)

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Wide-range Salusin Beta (SALb) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Wide-range Salusin Beta (SALb) and unlabeled Wide-range Salusin Beta (SALb) (Standards or samples) with the pre-coated antibody specific to Wide-range Salusin Beta (SALb). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Wide-range Salusin Beta (SALb) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Wide-range Salusin Beta (SALb) in the sample.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
CPC026Ra21 OVA Conjugated Salusin Beta (SALb) Immunogen; SDS-PAGE; WB.
CEC026Ra ELISA Kit for Salusin Beta (SALb) Enzyme-linked immunosorbent assay for Antigen Detection.
WEC026Ra Wide-range ELISA Kit for Salusin Beta (SALb) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC026Ra Multiplex Assay Kit for Salusin Beta (SALb) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSC026Ra11 ELISA Kit DIY Materials for Salusin Beta (SALb) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK