Wide-range ELISA Kit for Anti-Mullerian Hormone (AMH)
MIF; MIH; MIS; Müllerian Inhibiting Factor; Müllerian Inhibiting Hormone; Müllerian Inhibiting Substance
- Product No.WEA228Ra
- Organism SpeciesRattus norvegicus (Rat) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range123.5-10,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 50.1pg/mL.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 455
For more details, please contact local distributors!US$ 650
For more details, please contact local distributors! US$ 2925
For more details, please contact local distributors! US$ 5525
For more details, please contact local distributors! US$ 45500
For more details, please contact local distributors!
Specificity of the Wide-range ELISA Kit for Anti-Mullerian Hormone (AMH)
This assay has high sensitivity and excellent specificity for detection of Wide-range Anti-Mullerian Hormone (AMH).
No significant cross-reactivity or interference between Wide-range Anti-Mullerian Hormone (AMH) and analogues was observed.
Recovery of the Wide-range ELISA Kit for Anti-Mullerian Hormone (AMH)
Matrices listed below were spiked with certain level of recombinant Wide-range Anti-Mullerian Hormone (AMH) and the recovery rates were calculated by comparing the measured value to the expected amount of Wide-range Anti-Mullerian Hormone (AMH) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 93-101 | 97 |
EDTA plasma(n=5) | 78-97 | 83 |
heparin plasma(n=5) | 80-97 | 79 |
Precision of the Wide-range ELISA Kit for Anti-Mullerian Hormone (AMH)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Wide-range Anti-Mullerian Hormone (AMH) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Wide-range Anti-Mullerian Hormone (AMH) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Wide-range ELISA Kit for Anti-Mullerian Hormone (AMH)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Wide-range Anti-Mullerian Hormone (AMH) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 97-105% | 96-104% | 90-104% | 79-90% |
EDTA plasma(n=5) | 90-102% | 85-92% | 96-104% | 89-97% |
heparin plasma(n=5) | 88-104% | 94-101% | 87-94% | 95-103% |
Stability of the Wide-range ELISA Kit for Anti-Mullerian Hormone (AMH)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Wide-range ELISA Kit for Anti-Mullerian Hormone (AMH)
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
Test principle of the Wide-range ELISA Kit for Anti-Mullerian Hormone (AMH)
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Wide-range Anti-Mullerian Hormone (AMH) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Wide-range Anti-Mullerian Hormone (AMH) and unlabeled Wide-range Anti-Mullerian Hormone (AMH) (Standards or samples) with the pre-coated antibody specific to Wide-range Anti-Mullerian Hormone (AMH). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Wide-range Anti-Mullerian Hormone (AMH) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Wide-range Anti-Mullerian Hormone (AMH) in the sample.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Rattus norvegicus (Rat) | Applications (RESEARCH USE ONLY!) |
RPA228Ra01 | Recombinant Anti-Mullerian Hormone (AMH) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA228Ra01 | Polyclonal Antibody to Anti-Mullerian Hormone (AMH) | WB; IHC; ICC; IP. |
LAA228Ra71 | Biotin-Linked Polyclonal Antibody to Anti-Mullerian Hormone (AMH) | WB; IHC; ICC. |
MAA228Ra21 | Monoclonal Antibody to Anti-Mullerian Hormone (AMH) | WB; IHC; ICC; IP. |
CEA228Ra | ELISA Kit for Anti-Mullerian Hormone (AMH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
WEA228Ra | Wide-range ELISA Kit for Anti-Mullerian Hormone (AMH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCA228Ra | CLIA Kit for Anti-Mullerian Hormone (AMH) | Chemiluminescent immunoassay for Antigen Detection. |
LMA228Ra | Multiplex Assay Kit for Anti-Mullerian Hormone (AMH) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA228Ra11 | ELISA Kit DIY Materials for Anti-Mullerian Hormone (AMH) | Main materials for "Do It (ELISA Kit) Yourself". |