Multiplex Assay Kit for Phosphatidylinositol Trisphosphate (PIP3) ,etc. by FLIA (Flow Luminescence Immunoassay)
PtdIns(3,4,5)P3
(Note: Up to 8-plex in one testing reaction)
- Product No.ULMG856Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length3h
- Detection Range0.49-500ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.163 ng/mL.
- Sample TypeSerum, plasma and other biological fluids
- Download Instruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
-
FOB
US$ 287
For more details, please contact local distributors! US$ 298
For more details, please contact local distributors! US$ 315
For more details, please contact local distributors! US$ 337
For more details, please contact local distributors! US$ 359
For more details, please contact local distributors! US$ 392
For more details, please contact local distributors! US$ 442
For more details, please contact local distributors!US$ 552
For more details, please contact local distributors!
Specificity of the Multiplex Assay Kit for Phosphatidylinositol Trisphosphate (PIP3) ,etc. by FLIA (Flow Luminescence Immunoassay)
This assay has high sensitivity and excellent specificity for detection of Phosphatidylinositol Trisphosphate (PIP3).
No significant cross-reactivity or interference between Phosphatidylinositol Trisphosphate (PIP3) and analogues was observed.
Recovery of the Multiplex Assay Kit for Phosphatidylinositol Trisphosphate (PIP3) ,etc. by FLIA (Flow Luminescence Immunoassay)
Matrices listed below were spiked with certain level of recombinant Phosphatidylinositol Trisphosphate (PIP3) and the recovery rates were calculated by comparing the measured value to the expected amount of Phosphatidylinositol Trisphosphate (PIP3) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 84-104 | 99 |
| EDTA plasma(n=5) | 85-94 | 89 |
| heparin plasma(n=5) | 87-96 | 90 |
| sodium citrate plasma(n=5) | 89-103 | 95 |
Precision of the Multiplex Assay Kit for Phosphatidylinositol Trisphosphate (PIP3) ,etc. by FLIA (Flow Luminescence Immunoassay)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Phosphatidylinositol Trisphosphate (PIP3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Phosphatidylinositol Trisphosphate (PIP3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Multiplex Assay Kit for Phosphatidylinositol Trisphosphate (PIP3) ,etc. by FLIA (Flow Luminescence Immunoassay)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Phosphatidylinositol Trisphosphate (PIP3) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 82-105% | 83-103% | 87-94% | 99-105% |
| EDTA plasma(n=5) | 97-105% | 92-101% | 89-101% | 78-98% |
| heparin plasma(n=5) | 78-97% | 92-99% | 87-96% | 96-105% |
| sodium citrate plasma(n=5) | 79-102% | 81-97% | 82-98% | 94-105% |
Stability of the Multiplex Assay Kit for Phosphatidylinositol Trisphosphate (PIP3) ,etc. by FLIA (Flow Luminescence Immunoassay)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Multiplex Assay Kit for Phosphatidylinositol Trisphosphate (PIP3) ,etc. by FLIA (Flow Luminescence Immunoassay)
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 50μL standard or sample to each well, add 50μL prepared Detection Reagent A, add 10μL magnetic beads, and incubate 90 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
5. Wash plate once on magnetic frame;
6. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle of the Multiplex Assay Kit for Phosphatidylinositol Trisphosphate (PIP3) ,etc. by FLIA (Flow Luminescence Immunoassay)
Anti-Phosphatidylinositol Trisphosphate (PIP3) antibody was coated on the surface of magnetic beads. A competitive inhibition reaction is launched between biotin labeled Phosphatidylinositol Trisphosphate (PIP3) and unlabeled Phosphatidylinositol Trisphosphate (PIP3) (Standards or samples) with the pre-coated antibody specific to Phosphatidylinositol Trisphosphate (PIP3). PE-labeled avidin was added. The amount of bound PE conjugate is reverse proportional to the concentration of Phosphatidylinositol Trisphosphate (PIP3) in the sample, the intensity of MFI developed is reverse proportional to the concentration of Phosphatidylinositol Trisphosphate (PIP3) in the sample.
GIVEAWAYS
INCREMENT SERVICES
Related products
| Catalog No. | Organism species: Pan-species (General) | Applications (RESEARCH USE ONLY!) |
| UCEG856Ge | ELISA Kit for Phosphatidylinositol Trisphosphate (PIP3) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| UCMG856Ge | Multiplex Assay Kit for Phosphatidylinositol Trisphosphate (PIP3) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |
| ULMG856Ge | Multiplex Assay Kit for Phosphatidylinositol Trisphosphate (PIP3) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |