Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by FLIA (Flow Luminescence Immunoassay)

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Interleukin 31 (IL31).
No significant cross-reactivity or interference between Interleukin 31 (IL31) and analogues was observed.

Recovery of the Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Interleukin 31 (IL31) and the recovery rates were calculated by comparing the measured value to the expected amount of Interleukin 31 (IL31) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-97 94
EDTA plasma(n=5) 79-89 83
heparin plasma(n=5) 94-101 97

Precision of the Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 31 (IL31) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 31 (IL31) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interleukin 31 (IL31) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-103% 84-102% 97-104% 99-105%
EDTA plasma(n=5) 93-101% 80-99% 81-99% 89-96%
heparin plasma(n=5) 86-93% 94-103% 80-90% 81-93%

Stability of the Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by FLIA (Flow Luminescence Immunoassay)

Anti-Interleukin 31 (IL31) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Interleukin 31 (IL31) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Interleukin 31 (IL31) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Interleukin 31 (IL31) in the sample and corresponding value of MFI (Median Fluorescence Intensity).

GIVEAWAYS

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
UEPB179Ra63 Eukaryotic Interleukin 31 (IL31) Positive Control; Immunogen; SDS-PAGE; WB.
UEPB179Ra64 Eukaryotic Interleukin 31 (IL31) Positive Control; Immunogen; SDS-PAGE; WB.
UEPB179Ra61 Eukaryotic Interleukin 31 (IL31) Positive Control; Immunogen; SDS-PAGE; WB.
UEPB179Ra62 Eukaryotic Interleukin 31 (IL31) Positive Control; Immunogen; SDS-PAGE; WB.
URPB179Ra01 Recombinant Interleukin 31 (IL31) Positive Control; Immunogen; SDS-PAGE; WB.
UPAB179Ra01 Polyclonal Antibody to Interleukin 31 (IL31) WB
ULAB179Ra81 FITC-Linked Polyclonal Antibody to Interleukin 31 (IL31) WB; IHC; ICC; IF.
ULAB179Ra71 Biotin-Linked Polyclonal Antibody to Interleukin 31 (IL31) WB; IHC; ICC.
UMAB179Ra21 Monoclonal Antibody to Interleukin 31 (IL31) WB
USEB179Ra ELISA Kit for Interleukin 31 (IL31) Enzyme-linked immunosorbent assay for Antigen Detection.
UCMB179Ra Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
ULMB179Ra Multiplex Assay Kit for Interleukin 31 (IL31) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UKSB179Ra01 ELISA Kit DIY Materials for Interleukin 31 (IL31) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK