Multiplex Assay Kit for Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay)

IFNA1; IFL; LeIF D; IFN; IFN-Alpha; IFNA13; IFN-A; IFNAP22; IFN-Alpha 1b; Interferon Alpha 1b; Interferon, Leukocytic; IFN, Leukocyte; Interferon alpha-D

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 78-92 88
EDTA plasma(n=5) 88-95 91
heparin plasma(n=5) 92-105 99

Precision of the Multiplex Assay Kit for Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 84-99% 79-97% 92-101% 98-105%
EDTA plasma(n=5) 79-97% 85-93% 82-91% 85-98%
heparin plasma(n=5) 82-93% 92-99% 83-102% 94-105%

Stability of the Multiplex Assay Kit for Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Rhesus monkey (Simian) Applications (RESEARCH USE ONLY!)
RPA033Si01 Recombinant Interferon Alpha (IFNa) Positive Control; Immunogen; SDS-PAGE; WB.
PAA033Si01 Polyclonal Antibody to Interferon Alpha (IFNa) WB; IHC; ICC; IP.
MAA033Si21 Monoclonal Antibody to Interferon Alpha (IFNa) WB; IHC; ICC; IP.
SEA033Si ELISA Kit for Interferon Alpha (IFNa) Enzyme-linked immunosorbent assay for Antigen Detection.
IEA033Si Instant ELISA Kit for Interferon Alpha (IFNa) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA033Si CLIA Kit for Interferon Alpha (IFNa) Chemiluminescent immunoassay for Antigen Detection.
LMA033Si Multiplex Assay Kit for Interferon Alpha (IFNa) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK