Multiplex Assay Kit for Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay)
HFE2; HFE2A; HJV; JH; RGMC; hemochromatosis type 2(Juvenile); Haemojuvelin; RGM domain family member C
(Note: Up to 8-plex in one testing reaction)
- Product No.ULMB995Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length1.5h
- Detection Range0.98-1000ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.327 ng/mL.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
-
FOB
US$ 212
For more details, please contact local distributors! US$ 220
For more details, please contact local distributors! US$ 233
For more details, please contact local distributors! US$ 249
For more details, please contact local distributors! US$ 265
For more details, please contact local distributors! US$ 290
For more details, please contact local distributors! US$ 326
For more details, please contact local distributors!US$ 408
For more details, please contact local distributors!
Specificity of the Multiplex Assay Kit for Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay)
This assay has high sensitivity and excellent specificity for detection of Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.
Recovery of the Multiplex Assay Kit for Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay)
Matrices listed below were spiked with certain level of recombinant Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 88-98 | 94 |
EDTA plasma(n=5) | 80-97 | 87 |
heparin plasma(n=5) | 95-103 | 98 |
sodium citrate plasma(n=5) | 86-101 | 93 |
Precision of the Multiplex Assay Kit for Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Multiplex Assay Kit for Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 96-105% | 79-99% | 78-104% | 81-98% |
EDTA plasma(n=5) | 90-98% | 93-102% | 84-96% | 87-102% |
heparin plasma(n=5) | 86-95% | 89-99% | 86-102% | 90-101% |
sodium citrate plasma(n=5) | 98-105% | 98-105% | 90-101% | 89-101% |
Stability of the Multiplex Assay Kit for Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Multiplex Assay Kit for Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay)
1. Preparation of standards, reagents and samples before the experiment;
2. Add 50μL standard or sample to each well,
add 10μL magnetic beads,and 50μL Detection Reagent A,incubate 60min at 37°C on shaker;
3. Wash plate on magnetic frame for three times;
4. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
5. Wash plate on magnetic frame for three times;
6. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.
Test principle of the Multiplex Assay Kit for Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay)
Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards,Labeled antigen and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest.A competitive inhibition reaction is launched between biotin labeled analytes of interest and unlabeled analytes of interest (Standards or samples) with the pre-coated antibody specific to analytes of interest. Following a wash to remove any unbound substances, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE) is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer. The MFI developed is reverse proportional to the concentration of analytes of interest in the sample.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
URPB995Hu03 | Recombinant Hemojuvelin (HJV) | Positive Control; Immunogen; SDS-PAGE; WB. |
URPB995Hu02 | Recombinant Hemojuvelin (HJV) | Positive Control; Immunogen; SDS-PAGE; WB. |
UEPB995Hu61 | Eukaryotic Hemojuvelin (HJV) | Positive Control; Immunogen; SDS-PAGE; WB. |
URPB995Hu01 | Recombinant Hemojuvelin (HJV) | Positive Control; Immunogen; SDS-PAGE; WB. |
UAPB995Hu61 | Active Hemojuvelin (HJV) | Cell culture; Activity Assays. |
URPB995Hu04 | Recombinant Hemojuvelin (HJV) | Positive Control; Immunogen; SDS-PAGE; WB. |
UCPB995Hu22 | OVA Conjugated Hemojuvelin (HJV) | Immunogen; SDS-PAGE; WB. |
UCPB995Hu21 | OVA Conjugated Hemojuvelin (HJV) | Immunogen; SDS-PAGE; WB. |
UPAB995Hu04 | Polyclonal Antibody to Hemojuvelin (HJV) | WB; IHC |
UPAB995Hu06 | Polyclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
UPAB995Hu01 | Polyclonal Antibody to Hemojuvelin (HJV) | WB |
UPAB995Hu03 | Polyclonal Antibody to Hemojuvelin (HJV) | WB; IHC |
UPAB995Hu02 | Polyclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
UPAB995Hu08 | Polyclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
ULAB995Hu81 | FITC-Linked Polyclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IF. |
ULAB995Hu71 | Biotin-Linked Polyclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC. |
UMAB995Hu28 | Monoclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
UMAB995Hu24 | Monoclonal Antibody to Hemojuvelin (HJV) | WB |
UMAB995Hu27 | Monoclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
UMAB995Hu29 | Monoclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
UMAB995Hu26 | Monoclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
UMAB995Hu22 | Monoclonal Antibody to Hemojuvelin (HJV) | WB |
UMAB995Hu23 | Monoclonal Antibody to Hemojuvelin (HJV) | WB |
UMAB995Hu25 | Monoclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
UMAB995Hu21 | Monoclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IP. |
ULAB995Hu74 | Biotin-Linked Monoclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC. |
ULAB995Hu48 | PE-Linked Monoclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC; IF. |
ULAB995Hu76 | Biotin-Linked Monoclonal Antibody to Hemojuvelin (HJV) | WB; IHC; ICC. |
USEB995Hu | ELISA Kit for Hemojuvelin (HJV) | Enzyme-linked immunosorbent assay for Antigen Detection. |
UCEB995Hu | ELISA Kit for Hemojuvelin (HJV) | Enzyme-linked immunosorbent assay for Antigen Detection. |
ULMB995Hu | Multiplex Assay Kit for Hemojuvelin (HJV) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
UPSB995Hu01 | Antibody Pair for Hemojuvelin (HJV) | ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays. |
UKSB995Hu01 | ELISA Kit DIY Materials for Hemojuvelin (HJV) | Main materials for "Do It (ELISA Kit) Yourself". |