Magnetic Luminex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc.

HSP70-1; HSP-A1A; HSPA1; HSP70-2; HSX70

(Note: Up to 8-plex in one testing reaction)

  • Magnetic Luminex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. Packages (Simulation)
  • Magnetic Luminex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Magnetic Luminex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc.

This assay has high sensitivity and excellent specificity for detection of Heat Shock 70kDa Protein 1A (HSPA1A) ,etc..
No significant cross-reactivity or interference between Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. and analogues was observed.

Recovery of the Magnetic Luminex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc.

Matrices listed below were spiked with certain level of recombinant Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. and the recovery rates were calculated by comparing the measured value to the expected amount of Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-105 98
EDTA plasma(n=5) 78-99 87
heparin plasma(n=5) 88-101 95
sodium citrate plasma(n=5) 93-101 96

Precision of the Magnetic Luminex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc.

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Magnetic Luminex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc.

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 79-103% 81-91% 98-105% 78-104%
EDTA plasma(n=5) 88-95% 84-102% 97-105% 99-105%
heparin plasma(n=5) 78-99% 97-105% 91-98% 94-103%
sodium citrate plasma(n=5) 79-93% 85-101% 95-105% 78-94%

Stability of the Magnetic Luminex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc.

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Magnetic Luminex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc.

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Magnetic Luminex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc.

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPB081Hu02 Recombinant Heat Shock 70kDa Protein 1A (HSPA1A) Positive Control; Immunogen; SDS-PAGE; WB.
RPB081Hu01 Recombinant Heat Shock 70kDa Protein 1A (HSPA1A) Positive Control; Immunogen; SDS-PAGE; WB.
CAB081Hu01 Anti-Heat Shock 70kDa Protein 1A (HSPA1A) Polyclonal Antibody Loading Control of WB.
PAB081Hu01 Polyclonal Antibody to Heat Shock 70kDa Protein 1A (HSPA1A) WB; IHC; ICC; IP.
PAB081Hu02 Polyclonal Antibody to Heat Shock 70kDa Protein 1A (HSPA1A) WB,IHC
MAB081Hu21 Monoclonal Antibody to Heat Shock 70kDa Protein 1A (HSPA1A) WB,IHC,ICC/IF
MAB081Hu25 Monoclonal Antibody to Heat Shock 70kDa Protein 1A (HSPA1A) WB
CAB081Hu22 Anti-Heat Shock 70kDa Protein 1A (HSPA1A) Monoclonal Antibody Loading Control of WB.
MAB081Hu22 Monoclonal Antibody to Heat Shock 70kDa Protein 1A (HSPA1A) WB
FAB081Hu02 Anti-Heat Shock 70kDa Protein 1A (HSPA1A) Monoclonal Antibody Flow cytometry.
HEB081Hu High Sensitive ELISA Kit for Heat Shock 70kDa Protein 1A (HSPA1A) Enzyme-linked immunosorbent assay for Antigen Detection.
SEB081Hu ELISA Kit for Heat Shock 70kDa Protein 1A (HSPA1A) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB081Hu Magnetic Luminex Assay Kit for Heat Shock 70kDa Protein 1A (HSPA1A) ,etc. Magnetic Luminex Assay for Antigen Detection.
KSB081Hu01 ELISA Kit DIY Materials for Heat Shock 70kDa Protein 1A (HSPA1A) Main materials for "Do It (ELISA Kit) Yourself".
CGB081Hu01 cDNA of Heat Shock 70kDa Protein 1A (HSPA1A) PCR; Protein Expression; etc.
GUESTBOOK