Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by FLIA (Flow Luminescence Immunoassay)

Ferritin Light Chain; Ferritin Light Polypeptide-Like 3; L Apoferritin; Ferritin L Subunit

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Ferritin, Light Polypeptide (FTL).
No significant cross-reactivity or interference between Ferritin, Light Polypeptide (FTL) and analogues was observed.

Recovery of the Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Ferritin, Light Polypeptide (FTL) and the recovery rates were calculated by comparing the measured value to the expected amount of Ferritin, Light Polypeptide (FTL) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-99 94
EDTA plasma(n=5) 91-105 98
heparin plasma(n=5) 79-97 93

Precision of the Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ferritin, Light Polypeptide (FTL) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ferritin, Light Polypeptide (FTL) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ferritin, Light Polypeptide (FTL) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-99% 97-105% 79-102% 91-99%
EDTA plasma(n=5) 94-102% 96-105% 89-104% 91-101%
heparin plasma(n=5) 81-92% 82-105% 91-105% 92-101%

Stability of the Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by FLIA (Flow Luminescence Immunoassay)

Anti-Ferritin, Light Polypeptide (FTL) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Ferritin, Light Polypeptide (FTL) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Ferritin, Light Polypeptide (FTL) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Ferritin, Light Polypeptide (FTL) in the sample and corresponding value of MFI (Median Fluorescence Intensity).

GIVEAWAYS

Related products

Catalog No. Organism species: Equus caballus; Equine (Horse) Applications (RESEARCH USE ONLY!)
URPD020Eq01 Recombinant Ferritin, Light Polypeptide (FTL) Positive Control; Immunogen; SDS-PAGE; WB.
UPAD020Eq01 Polyclonal Antibody to Ferritin, Light Polypeptide (FTL) WB,IHC
ULAD020Eq71 Biotin-Linked Polyclonal Antibody to Ferritin, Light Polypeptide (FTL) WB
ULAD020Eq81 FITC-Linked Polyclonal Antibody to Ferritin, Light Polypeptide (FTL) WB; IHC; ICC; IF.
USED020Eq ELISA Kit for Ferritin, Light Polypeptide (FTL) Enzyme-linked immunosorbent assay for Antigen Detection.
UCMD020Eq Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by CBA (Cytometric Bead Array) FLIA Kit for Antigen Detection.
ULMD020Eq Multiplex Assay Kit for Ferritin, Light Polypeptide (FTL) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UKSD020Eq01 ELISA Kit DIY Materials for Ferritin, Light Polypeptide (FTL) Main materials for "Do It(ELISA Kit) Yourself"
GUESTBOOK