Multiplex Assay Kit for Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay)

Monocyte differentiation antigen CD14; Myeloid cell-specific leucine-rich glycoprotein

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-102 91
EDTA plasma(n=5) 95-103 101
heparin plasma(n=5) 90-97 94
sodium citrate plasma(n=5) 82-95 89

Precision of the Multiplex Assay Kit for Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 91-105% 83-102% 85-95%
EDTA plasma(n=5) 94-103% 79-90% 79-91% 79-98%
heparin plasma(n=5) 80-96% 90-97% 89-104% 90-104%
sodium citrate plasma(n=5) 78-96% 93-101% 83-104% 83-97%

Stability of the Multiplex Assay Kit for Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
EPA685Hu62 Eukaryotic Cluster Of Differentiation 14 (CD14) Positive Control; Immunogen; SDS-PAGE; WB.
APA685Hu62 Active Cluster Of Differentiation 14 (CD14) Cell culture; Activity Assays.
APA685Hu01 Active Cluster Of Differentiation 14 (CD14) Cell culture; Activity Assays.
RPA685Hu02 Recombinant Cluster Of Differentiation 14 (CD14) Positive Control; Immunogen; SDS-PAGE; WB.
RPA685Hu01 Recombinant Cluster Of Differentiation 14 (CD14) Positive Control; Immunogen; SDS-PAGE; WB.
APA685Hu61 Active Cluster Of Differentiation 14 (CD14) Cell culture; Activity Assays.
EPA685Hu61 Eukaryotic Cluster Of Differentiation 14 (CD14) Positive Control; Immunogen; SDS-PAGE; WB.
EPA685Hu64 Eukaryotic Cluster Of Differentiation 14 (CD14) Positive Control; Immunogen; SDS-PAGE; WB.
PAA685Hu01 Polyclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC; IP.
PAA685Hu06 Polyclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC; IP.
PAA685Hu02 Polyclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC; IP.
FAA685Hu01 Anti-Cluster Of Differentiation 14 (CD14) Polyclonal Antibody Flow cytometry.
FAA685Hu03 Anti-Cluster Of Differentiation 14 (CD14) Polyclonal Antibody Flow cytometry.
LAA685Hu71 Biotin-Linked Polyclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC.
MAA685Hu27 Monoclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC; IP.
MAA685Hu29 Monoclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC; IP.
MAA685Hu23 Monoclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC; IP.
MAA685Hu22 Monoclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC; IP.
MAA685Hu21 Monoclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC; IP.
MAA685Hu24 Monoclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC; IP.
MAA685Hu25 Monoclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC; IP.
MAA685Hu26 Monoclonal Antibody to Cluster Of Differentiation 14 (CD14) WB; IHC; ICC; IP.
RAA685Hu25 Recombinant Antibody to Cluster Of Differentiation 14 (CD14) WB; IF; ICC; IHC; IP; FCM.
FAA685Hu02 Anti-Cluster Of Differentiation 14 (CD14) Monoclonal Antibody FCM
FAA685Hu86 FITC-Linked Anti-Cluster Of Differentiation 14 (CD14) Monoclonal Antibody FCM
SEA685Hu ELISA Kit for Cluster Of Differentiation 14 (CD14) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA685Hu Multiplex Assay Kit for Cluster Of Differentiation 14 (CD14) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA685Hu01 ELISA Kit DIY Materials for Cluster Of Differentiation 14 (CD14) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK