Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay)

NTN; ABCD3; C3Xkine; CXC3; CXC3C; NTT; SCYD1; ABCD3; FKN; Neurotactin; Fractalkine; Small Inducible Cytokine Subfamily D(Cys-X3-Cys)Member 1

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 88-99 96
EDTA plasma(n=5) 94-102 97
heparin plasma(n=5) 78-99 90

Precision of the Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 91-98% 96-105% 86-101% 82-97%
EDTA plasma(n=5) 85-98% 97-104% 91-98% 84-103%
heparin plasma(n=5) 88-102% 94-103% 90-102% 97-104%

Stability of the Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
APA040Hu01 Active Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Cell culture; Activity Assays.
RPA040Hu02 Recombinant Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA040Hu01 Recombinant Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Positive Control; Immunogen; SDS-PAGE; WB.
APA040Hu02 Active Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Cell culture; Activity Assays.
PAA040Hu01 Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) WB; IHC; ICC; IP.
PAA040Hu02 Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) WB; IHC; ICC; IP.
LAA040Hu81 FITC-Linked Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) WB; IHC; ICC; IF.
LAA040Hu71 Biotin-Linked Polyclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) WB; IHC; ICC.
MAA040Hu22 Monoclonal Antibody to Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) WB; IHC; ICC; IP.
SEA040Hu ELISA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA040Hu CLIA Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Chemiluminescent immunoassay for Antigen Detection.
LMA040Hu Multiplex Assay Kit for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSA040Hu01 ELISA Kit DIY Materials for Chemokine C-X3-C-Motif Ligand 1 (CX3CL1) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK