Multiplex Assay Kit for Caudal Type Homeobox 2 (CDX2) ,etc. by FLIA (Flow Luminescence Immunoassay)
CDX3; Homeobox Protein CDX-2; Caudal Type Homeobox Transcription Factor 2
(Note: Up to 8-plex in one testing reaction)
- Product No.ULMC370Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range0.01-10ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.003 ng/mL.
- Sample TypeTissue homogenates, cell lysates and other biological fluids
- Download Instruction Manual
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
-
FOB
US$ 218
For more details, please contact local distributors! US$ 227
For more details, please contact local distributors! US$ 239
For more details, please contact local distributors! US$ 256
For more details, please contact local distributors! US$ 273
For more details, please contact local distributors! US$ 298
For more details, please contact local distributors! US$ 336
For more details, please contact local distributors!US$ 420
For more details, please contact local distributors!
Specificity of the Multiplex Assay Kit for Caudal Type Homeobox 2 (CDX2) ,etc. by FLIA (Flow Luminescence Immunoassay)
This assay has high sensitivity and excellent specificity for detection of Caudal Type Homeobox 2 (CDX2).
No significant cross-reactivity or interference between Caudal Type Homeobox 2 (CDX2) and analogues was observed.
Recovery of the Multiplex Assay Kit for Caudal Type Homeobox 2 (CDX2) ,etc. by FLIA (Flow Luminescence Immunoassay)
Matrices listed below were spiked with certain level of recombinant Caudal Type Homeobox 2 (CDX2) and the recovery rates were calculated by comparing the measured value to the expected amount of Caudal Type Homeobox 2 (CDX2) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 92-105 | 95 |
| EDTA plasma(n=5) | 85-102 | 95 |
| heparin plasma(n=5) | 78-102 | 91 |
Precision of the Multiplex Assay Kit for Caudal Type Homeobox 2 (CDX2) ,etc. by FLIA (Flow Luminescence Immunoassay)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Caudal Type Homeobox 2 (CDX2) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Caudal Type Homeobox 2 (CDX2) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Multiplex Assay Kit for Caudal Type Homeobox 2 (CDX2) ,etc. by FLIA (Flow Luminescence Immunoassay)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Caudal Type Homeobox 2 (CDX2) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 79-89% | 92-99% | 82-102% | 93-101% |
| EDTA plasma(n=5) | 88-96% | 84-96% | 89-97% | 86-96% |
| heparin plasma(n=5) | 84-101% | 98-105% | 83-102% | 91-101% |
Stability of the Multiplex Assay Kit for Caudal Type Homeobox 2 (CDX2) ,etc. by FLIA (Flow Luminescence Immunoassay)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Multiplex Assay Kit for Caudal Type Homeobox 2 (CDX2) ,etc. by FLIA (Flow Luminescence Immunoassay)
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle of the Multiplex Assay Kit for Caudal Type Homeobox 2 (CDX2) ,etc. by FLIA (Flow Luminescence Immunoassay)
Anti-Caudal Type Homeobox 2 (CDX2) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Caudal Type Homeobox 2 (CDX2) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Caudal Type Homeobox 2 (CDX2) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Caudal Type Homeobox 2 (CDX2) in the sample and corresponding value of MFI (Median Fluorescence Intensity).
GIVEAWAYS
INCREMENT SERVICES
Related products
| Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
| URPC370Hu01 | Recombinant Caudal Type Homeobox 2 (CDX2) | Positive Control; Immunogen; SDS-PAGE; WB. |
| UPAC370Hu01 | Polyclonal Antibody to Caudal Type Homeobox 2 (CDX2) | WB; IHC |
| UMAC370Hu21 | Monoclonal Antibody to Caudal Type Homeobox 2 (CDX2) | WB |
| UMAC370Hu23 | Monoclonal Antibody to Caudal Type Homeobox 2 (CDX2) | Testing in progress |
| UMAC370Hu22 | Monoclonal Antibody to Caudal Type Homeobox 2 (CDX2) | IHC |
| USEC370Hu | ELISA Kit for Caudal Type Homeobox 2 (CDX2) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| ULMC370Hu | Multiplex Assay Kit for Caudal Type Homeobox 2 (CDX2) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |