Multiplex Assay Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay)

BCL-XL/S; BCL2L1; BCLX; Bcl-X; bcl-xL; bcl-xS; Apoptosis regulator Bcl-X

(Note: Up to 8-plex in one testing reaction)

  • Multiplex Assay Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Multiplex Assay Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay) Packages (Simulation)
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the Multiplex Assay Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay)

This assay has high sensitivity and excellent specificity for detection of B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay).
No significant cross-reactivity or interference between B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay) and analogues was observed.

Recovery of the Multiplex Assay Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay)

Matrices listed below were spiked with certain level of recombinant B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay) and the recovery rates were calculated by comparing the measured value to the expected amount of B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 101
EDTA plasma(n=5) 80-95 87
heparin plasma(n=5) 85-97 90
sodium citrate plasma(n=5) 85-96 91

Precision of the Multiplex Assay Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the Multiplex Assay Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 97-105% 84-95% 92-99%
EDTA plasma(n=5) 95-103% 84-91% 95-102% 84-98%
heparin plasma(n=5) 94-103% 83-96% 79-94% 93-104%
sodium citrate plasma(n=5) 87-95% 83-101% 91-98% 93-101%

Stability of the Multiplex Assay Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the Multiplex Assay Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay)

1. Preparation of standards, reagents and samples before the experiment;
2. Add 100μL standard or sample to each well,
    add 10μL magnetic beads, and incubate 90min at 37°C on shaker;
3. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60min at 37°C on shaker;
4. Wash plate on magnetic frame for three times;
5. Add 100μL prepared Detection Reagent B, and incubate 30 min at 37°C on shaker;
6. Wash plate on magnetic frame for three times;
7. Add 100μL sheath solution, swirl for 2 minutes, read on the machine.

Test principle of the Multiplex Assay Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay)

Analyte-specific antibodies are pre-coated onto color-coded microparticles. Microparticles, standards, and samples are pipetted into wells and the immobilized antibodies bind the analytes of interest. After washing away any unbound substances, a biotinylated antibody cocktail specific to the analytes of interest is added to each well. Following a wash to remove any unbound biotinylated antibody, Streptavidin-Phycoerythrin conjugate (Streptavidin-PE), which binds to the biotinylated detection antibodies, is added to each well. A final wash removes unbound Streptavidin-PE and the microparticles are resuspended in buffer and read using the Luminex or Bio-Plex analyzer.The MFI developed is proportional to the concentration of analytes of interest in the sample.

GIVEAWAYS

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPE582Hu01 Recombinant B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) Positive Control; Immunogen; SDS-PAGE; WB.
PAE582Hu01 Polyclonal Antibody to B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) WB; IHC; ICC; IP; FCM
PAE582Hu02 Polyclonal Antibody to B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) WB; IHC; ICC; IP.
LAE582Hu71 Biotin-Linked Polyclonal Antibody to B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) WB; IHC; ICC.
SEE582Hu ELISA Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) Enzyme-linked immunosorbent assay for Antigen Detection.
LME582Hu Multiplex Assay Kit for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSE582Hu01 ELISA Kit DIY Materials for B-Cell CLL/Lymphoma 2 Like Protein (Bcl2L) Main materials for "Do It(ELISA Kit) Yourself"
GUESTBOOK