Multiplex Assay Kit for Complement 1q (C1q) ,etc. by FLIA (Flow Luminescence Immunoassay)
C1-q; Autoantigen Clq
(Note: Up to 8-plex in one testing reaction)
- Product No.ULMA747Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length4h
- Detection Range0.04-40ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.013ng/mL.
- Sample TypeSerum, plasma and other biological fluids
- Download n/a
- UOM 8Plex 7Plex 6Plex 5Plex 4Plex 3Plex 2Plex1Plex
-
FOB
US$ 202
For more details, please contact local distributors! US$ 210
For more details, please contact local distributors! US$ 222
For more details, please contact local distributors! US$ 237
For more details, please contact local distributors! US$ 253
For more details, please contact local distributors! US$ 276
For more details, please contact local distributors! US$ 311
For more details, please contact local distributors!US$ 389
For more details, please contact local distributors!
Specificity of the Multiplex Assay Kit for Complement 1q (C1q) ,etc. by FLIA (Flow Luminescence Immunoassay)
This assay has high sensitivity and excellent specificity for detection of Complement 1q (C1q).
No significant cross-reactivity or interference between Complement 1q (C1q) and analogues was observed.
Recovery of the Multiplex Assay Kit for Complement 1q (C1q) ,etc. by FLIA (Flow Luminescence Immunoassay)
Matrices listed below were spiked with certain level of recombinant Complement 1q (C1q) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement 1q (C1q) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 96-104 | 101 |
| EDTA plasma(n=5) | 88-104 | 101 |
| heparin plasma(n=5) | 81-103 | 92 |
Precision of the Multiplex Assay Kit for Complement 1q (C1q) ,etc. by FLIA (Flow Luminescence Immunoassay)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement 1q (C1q) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement 1q (C1q) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Multiplex Assay Kit for Complement 1q (C1q) ,etc. by FLIA (Flow Luminescence Immunoassay)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement 1q (C1q) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 80-90% | 97-105% | 96-104% | 96-105% |
| EDTA plasma(n=5) | 95-104% | 86-101% | 79-103% | 97-105% |
| heparin plasma(n=5) | 85-93% | 99-105% | 97-104% | 96-103% |
Stability of the Multiplex Assay Kit for Complement 1q (C1q) ,etc. by FLIA (Flow Luminescence Immunoassay)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Multiplex Assay Kit for Complement 1q (C1q) ,etc. by FLIA (Flow Luminescence Immunoassay)
1. Add 200μL analysis buffer solution to each well of the plate for pre-wetting;
2. Preparation of standards, reagents and samples before the experiment;
3. Add 100μL standard or sample to each well, add 10μL magnetic beads, and incubate 120 minutes protect from light at 25°C on shaker;
4. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent A. Incubate 60 minutes protect from light at 25°C on shaker;
5. Remove liquid on magnetic frame, add 100μL prepared Detection Reagent B, and incubate 30 minutes protect from light at 25°C on shaker;
6. Wash plate once on magnetic frame;
7. Add 100μL sheath fluid, swirl for 10 minutes, read on the machine.
Test principle of the Multiplex Assay Kit for Complement 1q (C1q) ,etc. by FLIA (Flow Luminescence Immunoassay)
Anti-Complement 1q (C1q) antibody was coated on the surface of magnetic beads, to make solid phase carrier. Standard or sample were added to the magnetic beads, respectively, in which Complement 1q (C1q) was bound to the antibody connected to the solid phase carrier, and then biotinylated anti-Complement 1q (C1q) antibodies were added. PE-labeled avidin was added. There is a positive correlation between the concentration of Complement 1q (C1q) in the sample and corresponding value of MFI (Median Fluorescence Intensity).
GIVEAWAYS
INCREMENT SERVICES
Related products
| Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
| UPAA747Hu01 | Polyclonal Antibody to Complement 1q (C1q) | IHC |
| ULAA747Hu71 | Biotin-Linked Polyclonal Antibody to Complement 1q (C1q) | IHC |
| USEA747Hu | ELISA Kit for Complement 1q (C1q) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| UOEA747Hu | OneStep ELISA Kit for Complement 1q (C1q) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| UAEA747Hu | ELISA Kit for Anti-Complement 1q Antibody (Anti-C1q) | Enzyme-linked immunosorbent assay for Antibody Detection. |
| UCMA747Hu | Multiplex Assay Kit for Complement 1q (C1q) ,etc. by CBA (Cytometric Bead Array) | FLIA Kit for Antigen Detection. |
| ULMA747Hu | Multiplex Assay Kit for Complement 1q (C1q) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
| UKSA747Hu01 | ELISA Kit DIY Materials for Complement 1q (C1q) | Main materials for "Do It (ELISA Kit) Yourself". |