Instant ELISA Kit for Thyroxine (T4)
3,5,3',5'-Tetraiodothyronine; L-Thyroxine; Levothyroxine
- Product No.IEA452Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length1h, 10min
- Detection Rangen/a
- Sensitivityn/a
- Sample Typen/a
- Download n/a
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 571
For more details, please contact local distributors!US$ 816
For more details, please contact local distributors! US$ 3672
For more details, please contact local distributors! US$ 6936
For more details, please contact local distributors! US$ 57120
For more details, please contact local distributors!
Specificity of the Instant ELISA Kit for Thyroxine (T4)
This assay has high sensitivity and excellent specificity for detection of Instant Thyroxine (T4).
No significant cross-reactivity or interference between Instant Thyroxine (T4) and analogues was observed.
Recovery of the Instant ELISA Kit for Thyroxine (T4)
Matrices listed below were spiked with certain level of Instant Thyroxine (T4) and the recovery rates were calculated by comparing the measured value to the expected amount of Instant Thyroxine (T4) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-98 | 90 |
EDTA plasma(n=5) | 78-104 | 84 |
heparin plasma(n=5) | 88-97 | 93 |
Precision of the Instant ELISA Kit for Thyroxine (T4)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Instant Thyroxine (T4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Instant Thyroxine (T4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Instant ELISA Kit for Thyroxine (T4)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Instant Thyroxine (T4) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 92-99% | 85-93% | 78-99% | 80-103% |
EDTA plasma(n=5) | 78-90% | 83-94% | 89-102% | 81-96% |
heparin plasma(n=5) | 80-101% | 98-105% | 88-104% | 79-96% |
Stability of the Instant ELISA Kit for Thyroxine (T4)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Instant ELISA Kit for Thyroxine (T4)
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 30 minutes at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 30 minutes at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 10 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the Instant ELISA Kit for Thyroxine (T4)
The test principle applied in this kit is enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Instant Thyroxine (T4). Standards or samples and HRP-labeled detection antibody specific to Instant Thyroxine (T4) (Detection Reagent A) are then added to the appropriate microtiter plate wells. Next, TMB substrate solution is added, only those wells that contain Instant Thyroxine (T4), and HRP-labeled detection antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Instant Thyroxine (T4) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Pan-species (General) | Applications (RESEARCH USE ONLY!) |
CPA452Ge11 | BSA Conjugated Thyroxine (T4) | Immunogen; SDS-PAGE; WB. |
CPA452Ge21 | OVA Conjugated Thyroxine (T4) | Immunogen; SDS-PAGE; WB. |
PAA452Ge01 | Polyclonal Antibody to Thyroxine (T4) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
LAA452Ge81 | FITC-Linked Polyclonal Antibody to Thyroxine (T4) | WB; IHC; ICC; IF. |
MAA452Ge28 | Monoclonal Antibody to Thyroxine (T4) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MAA452Ge25 | Monoclonal Antibody to Thyroxine (T4) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MAA452Ge23 | Monoclonal Antibody to Thyroxine (T4) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MAA452Ge22 | Monoclonal Antibody to Thyroxine (T4) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MAA452Ge21 | Monoclonal Antibody to Thyroxine (T4) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
CEA452Ge | ELISA Kit for Thyroxine (T4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
IEA452Ge | Instant ELISA Kit for Thyroxine (T4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
MEA452Ge | Mini Samples ELISA Kit for Thyroxine (T4) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCA452Ge | CLIA Kit for Thyroxine (T4) | Chemiluminescent immunoassay for Antigen Detection. |
LMA452Ge | Multiplex Assay Kit for Thyroxine (T4) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA452Ge11 | ELISA Kit DIY Materials for Thyroxine (T4) | Main materials for "Do It(ELISA Kit) Yourself" |