Instant ELISA Kit for Follicle Stimulating Hormone (FSH)
- Product No.IEA830Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length1h, 10min
- Detection Range0.78-50mIU/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.31mIU/mL.
- Sample TypeSerum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 420
For more details, please contact local distributors!US$ 600
For more details, please contact local distributors! US$ 2700
For more details, please contact local distributors! US$ 5100
For more details, please contact local distributors! US$ 42000
For more details, please contact local distributors!
Specificity of the Instant ELISA Kit for Follicle Stimulating Hormone (FSH)
This assay has high sensitivity and excellent specificity for detection of Instant Follicle Stimulating Hormone (FSH).
No significant cross-reactivity or interference between Instant Follicle Stimulating Hormone (FSH) and analogues was observed.
Recovery of the Instant ELISA Kit for Follicle Stimulating Hormone (FSH)
Matrices listed below were spiked with certain level of recombinant Instant Follicle Stimulating Hormone (FSH) and the recovery rates were calculated by comparing the measured value to the expected amount of Instant Follicle Stimulating Hormone (FSH) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 87-98 | 92 |
EDTA plasma(n=5) | 78-103 | 95 |
heparin plasma(n=5) | 89-103 | 92 |
Precision of the Instant ELISA Kit for Follicle Stimulating Hormone (FSH)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Instant Follicle Stimulating Hormone (FSH) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Instant Follicle Stimulating Hormone (FSH) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Instant ELISA Kit for Follicle Stimulating Hormone (FSH)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Instant Follicle Stimulating Hormone (FSH) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 91-98% | 90-98% | 97-104% | 79-93% |
EDTA plasma(n=5) | 80-93% | 78-89% | 90-104% | 93-105% |
heparin plasma(n=5) | 92-105% | 93-102% | 85-99% | 78-97% |
Stability of the Instant ELISA Kit for Follicle Stimulating Hormone (FSH)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Instant ELISA Kit for Follicle Stimulating Hormone (FSH)
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 30 minutes at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 30 minutes at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 10 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the Instant ELISA Kit for Follicle Stimulating Hormone (FSH)
The test principle applied in this kit is enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Instant Follicle Stimulating Hormone (FSH). Standards or samples and HRP-labeled detection antibody specific to Instant Follicle Stimulating Hormone (FSH) (Detection Reagent A) are then added to the appropriate microtiter plate wells. Next, TMB substrate solution is added, only those wells that contain Instant Follicle Stimulating Hormone (FSH), and HRP-labeled detection antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Instant Follicle Stimulating Hormone (FSH) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
RPA830Hu01 | Recombinant Follicle Stimulating Hormone (FSH) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA830Hu01 | Polyclonal Antibody to Follicle Stimulating Hormone (FSH) | WB; IHC; ICC; IP. |
MAA830Hu21 | Monoclonal Antibody to Follicle Stimulating Hormone (FSH) | WB; IHC; ICC; IP. |
SEA830Hu | ELISA Kit for Follicle Stimulating Hormone (FSH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
IEA830Hu | Instant ELISA Kit for Follicle Stimulating Hormone (FSH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA830Hu | ELISA Kit for Follicle Stimulating Hormone (FSH) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA830Hu | Multiplex Assay Kit for Follicle Stimulating Hormone (FSH) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
PGA830Hu01 | Primer Pair for Follicle Stimulating Hormone (FSH) | PCR |