Instant ELISA Kit for Dopamine (DA)
2-(3,4-Dihydroxyphenyl)ethylamine; 3,4-Dihydroxyphenethylamine; 3-Hydroxytyramine; Intropin; Revivan; Oxytyramine; Dopamine Hydrochloride
- Product No.IEA851Ge
- Organism SpeciesPan-species (General) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length1h, 10min
- Detection Rangen/a
- Sensitivityn/a
- Sample Typen/a
- Download n/a
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 836
For more details, please contact local distributors!US$ 1194
For more details, please contact local distributors! US$ 5373
For more details, please contact local distributors! US$ 10149
For more details, please contact local distributors! US$ 83580
For more details, please contact local distributors!
Specificity of the Instant ELISA Kit for Dopamine (DA)
This assay has high sensitivity and excellent specificity for detection of Instant Dopamine (DA).
No significant cross-reactivity or interference between Instant Dopamine (DA) and analogues was observed.
Recovery of the Instant ELISA Kit for Dopamine (DA)
Matrices listed below were spiked with certain level of Instant Dopamine (DA) and the recovery rates were calculated by comparing the measured value to the expected amount of Instant Dopamine (DA) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-91 | 84 |
EDTA plasma(n=5) | 90-104 | 94 |
heparin plasma(n=5) | 97-105 | 101 |
Precision of the Instant ELISA Kit for Dopamine (DA)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Instant Dopamine (DA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Instant Dopamine (DA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the Instant ELISA Kit for Dopamine (DA)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Instant Dopamine (DA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 82-97% | 91-99% | 84-101% | 80-97% |
EDTA plasma(n=5) | 80-105% | 85-99% | 87-94% | 82-102% |
heparin plasma(n=5) | 92-103% | 94-103% | 94-101% | 84-99% |
Stability of the Instant ELISA Kit for Dopamine (DA)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the Instant ELISA Kit for Dopamine (DA)
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 30 minutes at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 30 minutes at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 10 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the Instant ELISA Kit for Dopamine (DA)
The test principle applied in this kit is enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Instant Dopamine (DA). Standards or samples and HRP-labeled detection antibody specific to Instant Dopamine (DA) (Detection Reagent A) are then added to the appropriate microtiter plate wells. Next, TMB substrate solution is added, only those wells that contain Instant Dopamine (DA), and HRP-labeled detection antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Instant Dopamine (DA) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Pan-species (General) | Applications (RESEARCH USE ONLY!) |
CPA851Ge41 | HSA Conjugated Dopamine (DA) | Immunogen; SDS-PAGE; WB. |
CPA851Ge11 | BSA Conjugated Dopamine (DA) | Immunogen; SDS-PAGE; WB. |
CPA851Ge21 | OVA Conjugated Dopamine (DA) | Immunogen; SDS-PAGE; WB. |
PAA851Ge01 | Polyclonal Antibody to Dopamine (DA) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
LAA851Ge71 | Biotin-Linked Polyclonal Antibody to Dopamine (DA) | WB; IHC; ICC. |
LAA851Ge81 | FITC-Linked Polyclonal Antibody to Dopamine (DA) | WB; IHC; ICC; IF. |
MAA851Ge21 | Monoclonal Antibody to Dopamine (DA) | ELISA, CLIA. / IHC-Fr, ICC, IP (predicted). |
MEA851Ge | Mini Samples ELISA Kit for Dopamine (DA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CEA851Ge | ELISA Kit for Dopamine (DA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
IEA851Ge | Instant ELISA Kit for Dopamine (DA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
CCA851Ge | CLIA Kit for Dopamine (DA) | Chemiluminescent immunoassay for Antigen Detection. |
LMA851Ge | Multiplex Assay Kit for Dopamine (DA) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSA851Ge11 | ELISA Kit DIY Materials for Dopamine (DA) | Main materials for "Do It (ELISA Kit) Yourself". |