Specificity of the High Sensitive ELISA Kit for Thrombospondin 1 (THBS1)

This assay has high sensitivity and excellent specificity for detection of High Sensitive Thrombospondin 1 (THBS1).
No significant cross-reactivity or interference between High Sensitive Thrombospondin 1 (THBS1) and analogues was observed.

Recovery of the High Sensitive ELISA Kit for Thrombospondin 1 (THBS1)

Matrices listed below were spiked with certain level of recombinant High Sensitive Thrombospondin 1 (THBS1) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Thrombospondin 1 (THBS1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 92-101 97
heparin plasma(n=5) 78-96 86

Precision of the High Sensitive ELISA Kit for Thrombospondin 1 (THBS1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Thrombospondin 1 (THBS1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Thrombospondin 1 (THBS1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the High Sensitive ELISA Kit for Thrombospondin 1 (THBS1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Thrombospondin 1 (THBS1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 92-105% 78-92% 86-93% 94-102%
EDTA plasma(n=5) 96-105% 85-93% 78-98% 80-102%
heparin plasma(n=5) 88-99% 88-104% 95-105% 78-102%

Stability of the High Sensitive ELISA Kit for Thrombospondin 1 (THBS1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the High Sensitive ELISA Kit for Thrombospondin 1 (THBS1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the High Sensitive ELISA Kit for Thrombospondin 1 (THBS1)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Thrombospondin 1 (THBS1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Thrombospondin 1 (THBS1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Thrombospondin 1 (THBS1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Thrombospondin 1 (THBS1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA611Mu02 Recombinant Thrombospondin 1 (THBS1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA611Mu01 Recombinant Thrombospondin 1 (THBS1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA611Mu03 Recombinant Thrombospondin 1 (THBS1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA611Mu02 Polyclonal Antibody to Thrombospondin 1 (THBS1) WB; IHC; ICC; IP.
PAA611Mu01 Polyclonal Antibody to Thrombospondin 1 (THBS1) WB; IHC; ICC; IP.
PAA611Mu03 Polyclonal Antibody to Thrombospondin 1 (THBS1) WB; IHC; ICC; IP.
LAA611Mu71 Biotin-Linked Polyclonal Antibody to Thrombospondin 1 (THBS1) WB; IHC; ICC.
WEA611Mu Wide-range ELISA Kit for Thrombospondin 1 (THBS1) Enzyme-linked immunosorbent assay for Antigen Detection.
HEA611Mu High Sensitive ELISA Kit for Thrombospondin 1 (THBS1) Enzyme-linked immunosorbent assay for Antigen Detection.
SEA611Mu ELISA Kit for Thrombospondin 1 (THBS1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA611Mu CLIA Kit for Thrombospondin 1 (THBS1) Chemiluminescent immunoassay for Antigen Detection.
LMA611Mu Multiplex Assay Kit for Thrombospondin 1 (THBS1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK