High Sensitive ELISA Kit for Matrix Metalloproteinase 1 (MMP1)
CLGN; CLG1; Collagenase; Interstitial Collagenase; Vertebrate Collagenase; Fibroblast Collagenase
- Product No.HEA097Rb
- Organism SpeciesOryctolagus cuniculus (Rabbit) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range31.2-2000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 11.5pg/mL.
- Sample Typeserum, plasma and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 526
For more details, please contact local distributors!US$ 752
For more details, please contact local distributors! US$ 3384
For more details, please contact local distributors! US$ 6392
For more details, please contact local distributors! US$ 52640
For more details, please contact local distributors!
Specificity of the High Sensitive ELISA Kit for Matrix Metalloproteinase 1 (MMP1)
This assay has high sensitivity and excellent specificity for detection of High Sensitive Matrix Metalloproteinase 1 (MMP1).
No significant cross-reactivity or interference between High Sensitive Matrix Metalloproteinase 1 (MMP1) and analogues was observed.
Recovery of the High Sensitive ELISA Kit for Matrix Metalloproteinase 1 (MMP1)
Matrices listed below were spiked with certain level of recombinant High Sensitive Matrix Metalloproteinase 1 (MMP1) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Matrix Metalloproteinase 1 (MMP1) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 95-104 | 101 |
heparin plasma(n=5) | 78-103 | 94 |
Precision of the High Sensitive ELISA Kit for Matrix Metalloproteinase 1 (MMP1)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Matrix Metalloproteinase 1 (MMP1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Matrix Metalloproteinase 1 (MMP1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the High Sensitive ELISA Kit for Matrix Metalloproteinase 1 (MMP1)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Matrix Metalloproteinase 1 (MMP1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 99-105% | 87-94% | 82-90% | 86-97% |
heparin plasma(n=5) | 94-101% | 81-93% | 92-102% | 98-105% |
Stability of the High Sensitive ELISA Kit for Matrix Metalloproteinase 1 (MMP1)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the High Sensitive ELISA Kit for Matrix Metalloproteinase 1 (MMP1)
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the High Sensitive ELISA Kit for Matrix Metalloproteinase 1 (MMP1)
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Matrix Metalloproteinase 1 (MMP1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Matrix Metalloproteinase 1 (MMP1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Matrix Metalloproteinase 1 (MMP1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Matrix Metalloproteinase 1 (MMP1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Oryctolagus cuniculus (Rabbit) | Applications (RESEARCH USE ONLY!) |
RPA097Rb01 | Recombinant Matrix Metalloproteinase 1 (MMP1) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA097Rb51 | Polyclonal Antibody to Matrix Metalloproteinase 1 (MMP1) | WB; IHC; ICC; IP. |
MAA097Rb21 | Monoclonal Antibody to Matrix Metalloproteinase 1 (MMP1) | WB; IHC; ICC; IP. |
SEA097Rb | ELISA Kit for Matrix Metalloproteinase 1 (MMP1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
HEA097Rb | High Sensitive ELISA Kit for Matrix Metalloproteinase 1 (MMP1) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA097Rb | CLIA Kit for Matrix Metalloproteinase 1 (MMP1) | Chemiluminescent immunoassay for Antigen Detection. |
LMA097Rb | Multiplex Assay Kit for Matrix Metalloproteinase 1 (MMP1) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |