High Sensitive ELISA Kit for Immunoglobulin G (IgG)

  • High Sensitive ELISA Kit for Immunoglobulin G (IgG) Packages (Simulation)
  • High Sensitive ELISA Kit for Immunoglobulin G (IgG) Packages (Simulation)
  • High Sensitive ELISA Kit for Immunoglobulin G (IgG) Results demonstration
  • HEA544Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the High Sensitive ELISA Kit for Immunoglobulin G (IgG)

This assay has high sensitivity and excellent specificity for detection of High Sensitive Immunoglobulin G (IgG).
No significant cross-reactivity or interference between High Sensitive Immunoglobulin G (IgG) and analogues was observed.

Recovery of the High Sensitive ELISA Kit for Immunoglobulin G (IgG)

Matrices listed below were spiked with certain level of recombinant High Sensitive Immunoglobulin G (IgG) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Immunoglobulin G (IgG) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 90-99 93
EDTA plasma(n=5) 84-101 91
heparin plasma(n=5) 87-102 96

Precision of the High Sensitive ELISA Kit for Immunoglobulin G (IgG)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Immunoglobulin G (IgG) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Immunoglobulin G (IgG) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the High Sensitive ELISA Kit for Immunoglobulin G (IgG)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Immunoglobulin G (IgG) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-104% 81-101% 87-94% 99-105%
EDTA plasma(n=5) 78-104% 81-105% 90-98% 93-102%
heparin plasma(n=5) 85-103% 80-101% 80-104% 90-97%

Stability of the High Sensitive ELISA Kit for Immunoglobulin G (IgG)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the High Sensitive ELISA Kit for Immunoglobulin G (IgG)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the High Sensitive ELISA Kit for Immunoglobulin G (IgG)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Immunoglobulin G (IgG). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Immunoglobulin G (IgG). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Immunoglobulin G (IgG), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Immunoglobulin G (IgG) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
UNPA544Ra01 Native Immunoglobulin G (IgG) Positive Control; Immunogen; SDS-PAGE; WB.
URPA544Ra01 Recombinant Immunoglobulin G (IgG) Positive Control; Immunogen; SDS-PAGE; WB.
USAA544Ra00 None-Linked Rabbit Anti-Rat IgG Polyclonal Antibody WB; IHC; ICC; IF.
UPAA544Ra01 Polyclonal Antibody to Immunoglobulin G (IgG) WB; IHC; ICC; IP.
UPAA544Ra02 Polyclonal Antibody to Immunoglobulin G (IgG) WB; IHC; ICC; IP.
USAA544Ra06 Cy3-Linked Rabbit Anti-Rat IgG Polyclonal Antibody WB; IHC; ICC; IF.
USAA544Ra05 APC-Linked Rabbit Anti-Rat IgG Polyclonal Antibody WB; IHC; ICC; IF.
USAA544Ra04 PE-Linked Rabbit Anti-Rat IgG Polyclonal Antibody WB; IHC; ICC; IF.
USAA544Ra09 HRP-Linked Rabbit Anti-Rat IgG Polyclonal Antibody WB; IHC; ICC.
USAA544Ra07 Biotin-Linked Rabbit Anti-Rat IgG Polyclonal Antibody WB; IHC; ICC.
USAA544Ra08 FITC-Linked Rabbit Anti-Rat IgG Polyclonal Antibody WB; IHC; ICC; IF.
UMAA544Ra22 Monoclonal Antibody to Immunoglobulin G (IgG) WB; IHC; ICC; IP.
UMAA544Ra21 Monoclonal Antibody to Immunoglobulin G (IgG) WB
UHEA544Ra High Sensitive ELISA Kit for Immunoglobulin G (IgG) Enzyme-linked immunosorbent assay for Antigen Detection.
USEA544Ra ELISA Kit for Immunoglobulin G (IgG) Enzyme-linked immunosorbent assay for Antigen Detection.
UCEA544Ra ELISA Kit for Immunoglobulin G (IgG) Enzyme-linked immunosorbent assay for Antigen Detection.
UCCA544Ra CLIA Kit for Immunoglobulin G (IgG) Chemiluminescent immunoassay for Antigen Detection.
ULMA544Ra Multiplex Assay Kit for Immunoglobulin G (IgG) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
UKSA544Ra11 ELISA Kit DIY Materials for Immunoglobulin G (IgG) Main materials for "Do It (ELISA Kit) Yourself".