High Sensitive ELISA Kit for Coagulation Factor VII (F7)
FVII; SPCA; proconvertin; Cothromboplastin; Serum Prothrombin Conversation Accelerator; Stable Factor; Eptacog alfa
- Product No.HEB874Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range78-5,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 31pg/mL.
- Sample Typeplasma
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 526
For more details, please contact local distributors!US$ 752
For more details, please contact local distributors! US$ 3384
For more details, please contact local distributors! US$ 6392
For more details, please contact local distributors! US$ 52640
For more details, please contact local distributors!
Specificity of the High Sensitive ELISA Kit for Coagulation Factor VII (F7)
This assay has high sensitivity and excellent specificity for detection of High Sensitive Coagulation Factor VII (F7).
No significant cross-reactivity or interference between High Sensitive Coagulation Factor VII (F7) and analogues was observed.
Recovery of the High Sensitive ELISA Kit for Coagulation Factor VII (F7)
Matrices listed below were spiked with certain level of recombinant High Sensitive Coagulation Factor VII (F7) and the recovery rates were calculated by comparing the measured value to the expected amount of High Sensitive Coagulation Factor VII (F7) in samples.
Matrix | Recovery range (%) | Average(%) |
sodium citrate plasma(n=5) | 87-102 | 92 |
Precision of the High Sensitive ELISA Kit for Coagulation Factor VII (F7)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level High Sensitive Coagulation Factor VII (F7) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level High Sensitive Coagulation Factor VII (F7) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the High Sensitive ELISA Kit for Coagulation Factor VII (F7)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of High Sensitive Coagulation Factor VII (F7) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
sodium citrate plasma(n=5) | 80-91% | 87-105% | 84-102% | 82-97% |
Stability of the High Sensitive ELISA Kit for Coagulation Factor VII (F7)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the High Sensitive ELISA Kit for Coagulation Factor VII (F7)
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the High Sensitive ELISA Kit for Coagulation Factor VII (F7)
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to High Sensitive Coagulation Factor VII (F7). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to High Sensitive Coagulation Factor VII (F7). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain High Sensitive Coagulation Factor VII (F7), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of High Sensitive Coagulation Factor VII (F7) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Mus musculus (Mouse) | Applications (RESEARCH USE ONLY!) |
RPB874Mu01 | Recombinant Coagulation Factor VII (F7) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPB874Mu02 | Recombinant Coagulation Factor VII (F7) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAB874Mu02 | Polyclonal Antibody to Coagulation Factor VII (F7) | WB; IHC; ICC; IP. |
PAB874Mu01 | Polyclonal Antibody to Coagulation Factor VII (F7) | WB; IHC; ICC; IP. |
LAB874Mu71 | Biotin-Linked Polyclonal Antibody to Coagulation Factor VII (F7) | WB; IHC; ICC. |
HEB874Mu | High Sensitive ELISA Kit for Coagulation Factor VII (F7) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SEB874Mu | ELISA Kit for Coagulation Factor VII (F7) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB874Mu | Multiplex Assay Kit for Coagulation Factor VII (F7) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSB874Mu01 | ELISA Kit DIY Materials for Coagulation Factor VII (F7) | Main materials for "Do It (ELISA Kit) Yourself". |