ELISA Kit for Lipase A, Lysosomal Acid (LIPA)

LAL; CESD; Lipase A,Lysosomal Acid,Cholesterol Esterase(Wolman Disease); Acid Cholesteryl Ester Hydrolase; Lysosomal acid lipase/cholesteryl ester hydrolase

  • ELISA Kit for Lipase A, Lysosomal Acid (LIPA) Packages (Simulation)
  • ELISA Kit for Lipase A, Lysosomal Acid (LIPA) Packages (Simulation)
  • ELISA Kit for Lipase A, Lysosomal Acid (LIPA) Results demonstration
  • SED225Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Lipase A, Lysosomal Acid (LIPA)

This assay has high sensitivity and excellent specificity for detection of Lipase A, Lysosomal Acid (LIPA).
No significant cross-reactivity or interference between Lipase A, Lysosomal Acid (LIPA) and analogues was observed.

Recovery of the ELISA Kit for Lipase A, Lysosomal Acid (LIPA)

Matrices listed below were spiked with certain level of recombinant Lipase A, Lysosomal Acid (LIPA) and the recovery rates were calculated by comparing the measured value to the expected amount of Lipase A, Lysosomal Acid (LIPA) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 94-102 99
EDTA plasma(n=5) 88-103 94
heparin plasma(n=5) 80-93 86

Precision of the ELISA Kit for Lipase A, Lysosomal Acid (LIPA)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Lipase A, Lysosomal Acid (LIPA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Lipase A, Lysosomal Acid (LIPA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Lipase A, Lysosomal Acid (LIPA)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Lipase A, Lysosomal Acid (LIPA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 93-101% 79-93% 96-104% 87-105%
EDTA plasma(n=5) 97-105% 90-97% 78-104% 98-105%
heparin plasma(n=5) 84-97% 94-101% 80-94% 83-104%

Stability of the ELISA Kit for Lipase A, Lysosomal Acid (LIPA)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Lipase A, Lysosomal Acid (LIPA)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Lipase A, Lysosomal Acid (LIPA)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Lipase A, Lysosomal Acid (LIPA). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Lipase A, Lysosomal Acid (LIPA). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Lipase A, Lysosomal Acid (LIPA), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Lipase A, Lysosomal Acid (LIPA) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPD225Mu01 Recombinant Lipase A, Lysosomal Acid (LIPA) Positive Control; Immunogen; SDS-PAGE; WB.
RPD225Mu02 Recombinant Lipase A, Lysosomal Acid (LIPA) Positive Control; Immunogen; SDS-PAGE; WB.
PAD225Mu02 Polyclonal Antibody to Lipase A, Lysosomal Acid (LIPA) WB; IHC; ICC; IP.
PAD225Mu01 Polyclonal Antibody to Lipase A, Lysosomal Acid (LIPA) WB; IHC; ICC; IP.
SED225Mu ELISA Kit for Lipase A, Lysosomal Acid (LIPA) Enzyme-linked immunosorbent assay for Antigen Detection.
LMD225Mu Multiplex Assay Kit for Lipase A, Lysosomal Acid (LIPA) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK