ELISA Kit for Mucin 17 (MUC17)

MUC3; Mucin Cell Surface Associated; Small intestinal mucin-3

  • ELISA Kit for Mucin 17 (MUC17) Packages (Simulation)
  • ELISA Kit for Mucin 17 (MUC17) Packages (Simulation)
  • ELISA Kit for Mucin 17 (MUC17) Results demonstration
  • SEA403Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Mucin 17 (MUC17)

This assay has high sensitivity and excellent specificity for detection of Mucin 17 (MUC17).
No significant cross-reactivity or interference between Mucin 17 (MUC17) and analogues was observed.

Recovery of the ELISA Kit for Mucin 17 (MUC17)

Matrices listed below were spiked with certain level of recombinant Mucin 17 (MUC17) and the recovery rates were calculated by comparing the measured value to the expected amount of Mucin 17 (MUC17) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 92-102 97
EDTA plasma(n=5) 80-89 83
heparin plasma(n=5) 93-101 96

Precision of the ELISA Kit for Mucin 17 (MUC17)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mucin 17 (MUC17) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mucin 17 (MUC17) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Mucin 17 (MUC17)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mucin 17 (MUC17) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-98% 96-105% 95-104% 81-101%
EDTA plasma(n=5) 78-104% 93-105% 98-105% 98-105%
heparin plasma(n=5) 80-90% 89-98% 98-105% 96-103%

Stability of the ELISA Kit for Mucin 17 (MUC17)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Mucin 17 (MUC17)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Mucin 17 (MUC17)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mucin 17 (MUC17). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Mucin 17 (MUC17). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mucin 17 (MUC17), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mucin 17 (MUC17) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPA403Hu01 Recombinant Mucin 17 (MUC17) Positive Control; Immunogen; SDS-PAGE; WB.
PAA403Hu01 Polyclonal Antibody to Mucin 17 (MUC17) WB; IHC; ICC; IP.
MAA403Hu22 Monoclonal Antibody to Mucin 17 (MUC17) WB; IHC; ICC; IP.
SEA403Hu ELISA Kit for Mucin 17 (MUC17) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA403Hu Multiplex Assay Kit for Mucin 17 (MUC17) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK