ELISA Kit for Fibrinopeptide A (FPA)
FP-A
- Product No.CEB237Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodCompetitive Inhibition
- Assay Length2h
- Detection Range1.23-100ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.55ng/mL.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 466
For more details, please contact local distributors!US$ 665
For more details, please contact local distributors! US$ 2993
For more details, please contact local distributors! US$ 5653
For more details, please contact local distributors! US$ 46550
For more details, please contact local distributors!
Specificity of the ELISA Kit for Fibrinopeptide A (FPA)
This assay has high sensitivity and excellent specificity for detection of Fibrinopeptide A (FPA).
No significant cross-reactivity or interference between Fibrinopeptide A (FPA) and analogues was observed.
Recovery of the ELISA Kit for Fibrinopeptide A (FPA)
Matrices listed below were spiked with certain level of recombinant Fibrinopeptide A (FPA) and the recovery rates were calculated by comparing the measured value to the expected amount of Fibrinopeptide A (FPA) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 95-102 | 99 |
EDTA plasma(n=5) | 79-101 | 87 |
heparin plasma(n=5) | 78-90 | 83 |
Precision of the ELISA Kit for Fibrinopeptide A (FPA)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibrinopeptide A (FPA) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibrinopeptide A (FPA) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the ELISA Kit for Fibrinopeptide A (FPA)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Fibrinopeptide A (FPA) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 96-103% | 87-103% | 84-96% | 97-105% |
EDTA plasma(n=5) | 88-96% | 91-98% | 84-91% | 82-96% |
heparin plasma(n=5) | 78-102% | 93-101% | 78-88% | 80-97% |
Stability of the ELISA Kit for Fibrinopeptide A (FPA)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the ELISA Kit for Fibrinopeptide A (FPA)
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
And then add 50µL prepared Detection Reagent A immediately.
Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.
Test principle of the ELISA Kit for Fibrinopeptide A (FPA)
This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Fibrinopeptide A (FPA) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Fibrinopeptide A (FPA) and unlabeled Fibrinopeptide A (FPA) (Standards or samples) with the pre-coated antibody specific to Fibrinopeptide A (FPA). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Fibrinopeptide A (FPA) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Fibrinopeptide A (FPA) in the sample.
GIVEAWAYS
INCREMENT SERVICES
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
SPB237Hu01 | Synthetic Fibrinopeptide A (FPA) | Immunogen; Blocking Peptide. |
CPB237Hu22 | OVA Conjugated Fibrinopeptide A (FPA) | Immunogen; SDS-PAGE; WB. |
CPB237Hu21 | OVA Conjugated Fibrinopeptide A (FPA) | Immunogen; SDS-PAGE; WB. |
PAB237Hu01 | Polyclonal Antibody to Fibrinopeptide A (FPA) | WB; IHC; ICC; IP. |
CEB237Hu | ELISA Kit for Fibrinopeptide A (FPA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMB237Hu | Multiplex Assay Kit for Fibrinopeptide A (FPA) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |
KSB237Hu11 | ELISA Kit DIY Materials for Fibrinopeptide A (FPA) | Main materials for "Do It (ELISA Kit) Yourself". |