ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3)

HNP3; DEF3; HNP-2; Neutrophil defensin 2

  • ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3) Packages (Simulation)
  • ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3) Packages (Simulation)
  • ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3) Results demonstration
  • SEE135Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3)

This assay has high sensitivity and excellent specificity for detection of Defensin Alpha 3, Neutrophil Specific (DEFa3).
No significant cross-reactivity or interference between Defensin Alpha 3, Neutrophil Specific (DEFa3) and analogues was observed.

Recovery of the ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3)

Matrices listed below were spiked with certain level of recombinant Defensin Alpha 3, Neutrophil Specific (DEFa3) and the recovery rates were calculated by comparing the measured value to the expected amount of Defensin Alpha 3, Neutrophil Specific (DEFa3) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 95-105 101
EDTA plasma(n=5) 78-90 86
heparin plasma(n=5) 88-97 91

Precision of the ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Defensin Alpha 3, Neutrophil Specific (DEFa3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Defensin Alpha 3, Neutrophil Specific (DEFa3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Defensin Alpha 3, Neutrophil Specific (DEFa3) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-103% 80-92% 86-95% 82-97%
EDTA plasma(n=5) 82-93% 98-105% 97-105% 81-104%
heparin plasma(n=5) 78-97% 84-104% 90-98% 87-95%

Stability of the ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Defensin Alpha 3, Neutrophil Specific (DEFa3). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Defensin Alpha 3, Neutrophil Specific (DEFa3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Defensin Alpha 3, Neutrophil Specific (DEFa3), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Defensin Alpha 3, Neutrophil Specific (DEFa3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPE135Hu01 Recombinant Defensin Alpha 3, Neutrophil Specific (DEFa3) Positive Control; Immunogen; SDS-PAGE; WB.
RPE135Hu02 Recombinant Defensin Alpha 3, Neutrophil Specific (DEFa3) Positive Control; Immunogen; SDS-PAGE; WB.
PAE135Hu01 Polyclonal Antibody to Defensin Alpha 3, Neutrophil Specific (DEFa3) WB; IHC; ICC; IP.
PAE135Hu02 Polyclonal Antibody to Defensin Alpha 3, Neutrophil Specific (DEFa3) WB,IHC
LAE135Hu81 FITC-Linked Polyclonal Antibody to Defensin Alpha 3, Neutrophil Specific (DEFa3) WB; IHC; ICC; IF.
LAE135Hu71 Biotin-Linked Polyclonal Antibody to Defensin Alpha 3, Neutrophil Specific (DEFa3) WB; IHC; ICC.
SEE135Hu ELISA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3) Enzyme-linked immunosorbent assay for Antigen Detection.
SCE135Hu CLIA Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3) Chemiluminescent immunoassay for Antigen Detection.
LME135Hu Multiplex Assay Kit for Defensin Alpha 3, Neutrophil Specific (DEFa3) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSE135Hu01 ELISA Kit DIY Materials for Defensin Alpha 3, Neutrophil Specific (DEFa3) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK