ELISA Kit for Complement Component 3 (C3)
ASP; CPAMD1; Complement Protein C3; C3 and PZP-like alpha-2-macroglobulin domain-containing protein 1; C3a anaphylatoxin; Acylation stimulating protein
- Product No.SEA861Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range7.8-500ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 3.5ng/mL.
- Sample Typeserum, plasma and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 307
For more details, please contact local distributors!US$ 439
For more details, please contact local distributors! US$ 1976
For more details, please contact local distributors! US$ 3732
For more details, please contact local distributors! US$ 30730
For more details, please contact local distributors!
Specificity of the ELISA Kit for Complement Component 3 (C3)
This assay has high sensitivity and excellent specificity for detection of Complement Component 3 (C3).
No significant cross-reactivity or interference between Complement Component 3 (C3) and analogues was observed.
Recovery of the ELISA Kit for Complement Component 3 (C3)
Matrices listed below were spiked with certain level of recombinant Complement Component 3 (C3) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement Component 3 (C3) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 78-92 | 88 |
EDTA plasma(n=5) | 87-102 | 92 |
heparin plasma(n=5) | 93-101 | 97 |
Precision of the ELISA Kit for Complement Component 3 (C3)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Component 3 (C3) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Component 3 (C3) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the ELISA Kit for Complement Component 3 (C3)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement Component 3 (C3) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 90-98% | 81-98% | 91-98% | 95-105% |
EDTA plasma(n=5) | 91-105% | 89-98% | 99-105% | 88-102% |
heparin plasma(n=5) | 79-93% | 89-96% | 89-96% | 78-92% |
Stability of the ELISA Kit for Complement Component 3 (C3)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the ELISA Kit for Complement Component 3 (C3)
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the ELISA Kit for Complement Component 3 (C3)
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Complement Component 3 (C3). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Complement Component 3 (C3). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Complement Component 3 (C3), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Complement Component 3 (C3) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
INCREMENT SERVICES
Single-component Reagents of Assay Kit
Lysis Buffer Specific for ELISA / CLIA
Quality Control of Kit
ELISA Kit Customized Service
Disease Model Customized Service
Serums Customized Service
TGFB1 Activation Reagent
Real Time PCR Experimental Service
Streptavidin
Fast blue Protein Stain solution
Single-component Reagents of FLIA Kit
Streptavidin-Agarose Beads
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
RPA861Hu01 | Recombinant Complement Component 3 (C3) | Positive Control; Immunogen; SDS-PAGE; WB. |
APA861Hu01 | Active Complement Component 3 (C3) | Cell culture; Activity Assays. |
PAA861Hu01 | Polyclonal Antibody to Complement Component 3 (C3) | WB; IHC; ICC; IP; FCM |
LAA861Hu81 | FITC-Linked Polyclonal Antibody to Complement Component 3 (C3) | WB; IHC; ICC; IF. |
LAA861Hu71 | Biotin-Linked Polyclonal Antibody to Complement Component 3 (C3) | WB; IHC; ICC. |
MAA861Hu22 | Monoclonal Antibody to Complement Component 3 (C3) | WB; IHC; ICC; IP. |
SEA861Hu | ELISA Kit for Complement Component 3 (C3) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA861Hu | Multiplex Assay Kit for Complement Component 3 (C3) ,etc. by FLIA (Flow Luminescence Immunoassay) | FLIA Kit for Antigen Detection. |