ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM)

GLCLR; GECS; GCL; Gamma Glutamylcysteine Synthetase; Glutamate Cysteine Ligase Regulatory; Gamma-ECS regulatory subunit; Glutamate cysteine ligase modifier subunit

  • ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM) Packages (Simulation)
  • ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM) Packages (Simulation)
  • ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM) Results demonstration
  • SEB038Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM)

This assay has high sensitivity and excellent specificity for detection of Glutamate Cysteine Ligase, Modifier Subunit (GCLM).
No significant cross-reactivity or interference between Glutamate Cysteine Ligase, Modifier Subunit (GCLM) and analogues was observed.

Recovery of the ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM)

Matrices listed below were spiked with certain level of recombinant Glutamate Cysteine Ligase, Modifier Subunit (GCLM) and the recovery rates were calculated by comparing the measured value to the expected amount of Glutamate Cysteine Ligase, Modifier Subunit (GCLM) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-96 93
EDTA plasma(n=5) 91-99 95
heparin plasma(n=5) 82-101 94

Precision of the ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutamate Cysteine Ligase, Modifier Subunit (GCLM) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutamate Cysteine Ligase, Modifier Subunit (GCLM) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutamate Cysteine Ligase, Modifier Subunit (GCLM) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 78-105% 88-96% 79-101%
EDTA plasma(n=5) 94-103% 84-104% 93-102% 79-101%
heparin plasma(n=5) 83-101% 88-102% 94-105% 79-101%

Stability of the ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Glutamate Cysteine Ligase, Modifier Subunit (GCLM). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Glutamate Cysteine Ligase, Modifier Subunit (GCLM). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Glutamate Cysteine Ligase, Modifier Subunit (GCLM), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Glutamate Cysteine Ligase, Modifier Subunit (GCLM) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPB038Mu01 Recombinant Glutamate Cysteine Ligase, Modifier Subunit (GCLM) Positive Control; Immunogen; SDS-PAGE; WB.
RPB038Mu02 Recombinant Glutamate Cysteine Ligase, Modifier Subunit (GCLM) Positive Control; Immunogen; SDS-PAGE; WB.
PAB038Mu01 Polyclonal Antibody to Glutamate Cysteine Ligase, Modifier Subunit (GCLM) WB; IHC; ICC; IP.
PAB038Mu02 Polyclonal Antibody to Glutamate Cysteine Ligase, Modifier Subunit (GCLM) WB; IHC; ICC; IP.
SEB038Mu ELISA Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM) Enzyme-linked immunosorbent assay for Antigen Detection.
LMB038Mu Multiplex Assay Kit for Glutamate Cysteine Ligase, Modifier Subunit (GCLM) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK