ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC)

GCS; GLCL; GLCLC; Gamma-glutamylcysteine synthetase; Gamma-ECS

  • ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC) Packages (Simulation)
  • ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC) Packages (Simulation)
  • ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC) Results demonstration
  • SED759Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC)

This assay has high sensitivity and excellent specificity for detection of Glutamate Cysteine Ligase, Catalytic (GCLC).
No significant cross-reactivity or interference between Glutamate Cysteine Ligase, Catalytic (GCLC) and analogues was observed.

Recovery of the ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC)

Matrices listed below were spiked with certain level of recombinant Glutamate Cysteine Ligase, Catalytic (GCLC) and the recovery rates were calculated by comparing the measured value to the expected amount of Glutamate Cysteine Ligase, Catalytic (GCLC) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 82-90 85
EDTA plasma(n=5) 91-99 95
heparin plasma(n=5) 85-97 89

Precision of the ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glutamate Cysteine Ligase, Catalytic (GCLC) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glutamate Cysteine Ligase, Catalytic (GCLC) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Glutamate Cysteine Ligase, Catalytic (GCLC) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-99% 79-95% 78-92% 80-98%
EDTA plasma(n=5) 79-102% 98-105% 92-103% 78-104%
heparin plasma(n=5) 80-96% 98-105% 88-101% 98-105%

Stability of the ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Glutamate Cysteine Ligase, Catalytic (GCLC). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Glutamate Cysteine Ligase, Catalytic (GCLC). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Glutamate Cysteine Ligase, Catalytic (GCLC), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Glutamate Cysteine Ligase, Catalytic (GCLC) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
RPD759Ra01 Recombinant Glutamate Cysteine Ligase, Catalytic (GCLC) Positive Control; Immunogen; SDS-PAGE; WB.
PAD759Ra01 Polyclonal Antibody to Glutamate Cysteine Ligase, Catalytic (GCLC) WB; IHC; ICC; IP.
MAD759Ra21 Monoclonal Antibody to Glutamate Cysteine Ligase, Catalytic (GCLC) WB; IHC; ICC; IP.
SED759Ra ELISA Kit for Glutamate Cysteine Ligase, Catalytic (GCLC) Enzyme-linked immunosorbent assay for Antigen Detection.
LMD759Ra Multiplex Assay Kit for Glutamate Cysteine Ligase, Catalytic (GCLC) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK