ELISA Kit for Chemerin (CHEM)
TIG2; RARRES2; Tazarotene-Induced Gene 2; Retinoic Acid Receptor Responder 2,Tazarotene Induced; RAR-responsive protein TIG2
- Product No.SEA945Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range0.78-50ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.32ng/mL.
- Sample Typeserum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 319
For more details, please contact local distributors!US$ 455
For more details, please contact local distributors! US$ 2048
For more details, please contact local distributors! US$ 3868
For more details, please contact local distributors! US$ 31850
For more details, please contact local distributors!
Specificity of the ELISA Kit for Chemerin (CHEM)
This assay has high sensitivity and excellent specificity for detection of Chemerin (CHEM).
No significant cross-reactivity or interference between Chemerin (CHEM) and analogues was observed.
Recovery of the ELISA Kit for Chemerin (CHEM)
Matrices listed below were spiked with certain level of recombinant Chemerin (CHEM) and the recovery rates were calculated by comparing the measured value to the expected amount of Chemerin (CHEM) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 80-94 | 89 |
EDTA plasma(n=5) | 81-95 | 88 |
heparin plasma(n=5) | 89-102 | 95 |
Precision of the ELISA Kit for Chemerin (CHEM)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Chemerin (CHEM) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Chemerin (CHEM) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity of the ELISA Kit for Chemerin (CHEM)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Chemerin (CHEM) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 97-105% | 86-104% | 86-102% | 95-105% |
EDTA plasma(n=5) | 83-97% | 95-102% | 80-90% | 83-97% |
heparin plasma(n=5) | 89-96% | 87-103% | 86-101% | 79-97% |
Stability of the ELISA Kit for Chemerin (CHEM)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the ELISA Kit for Chemerin (CHEM)
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the ELISA Kit for Chemerin (CHEM)
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Chemerin (CHEM). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Chemerin (CHEM). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Chemerin (CHEM), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Chemerin (CHEM) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
INCREMENT SERVICES
Single-component Reagents of Assay Kit
Lysis Buffer Specific for ELISA / CLIA
Quality Control of ELISA / CLIA
ELISA Kit Customized Service
Disease Model Customized Service
Serums Customized Service
TGFB1 Activation Reagent
Real Time PCR Experimental Service
Streptavidin
Fast blue Protein Stain solution
Single-component Reagents of Magnetic Luminex Assay Kit
Related products
Catalog No. | Organism species: Mus musculus (Mouse) | Applications (RESEARCH USE ONLY!) |
RPA945Mu01 | Recombinant Chemerin (CHEM) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA945Mu02 | Recombinant Chemerin (CHEM) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA945Mu02 | Polyclonal Antibody to Chemerin (CHEM) | WB; IHC; ICC; IP. |
PAA945Mu01 | Polyclonal Antibody to Chemerin (CHEM) | WB,IHC |
SEA945Mu | ELISA Kit for Chemerin (CHEM) | Enzyme-linked immunosorbent assay for Antigen Detection. |
LMA945Mu | Magnetic Luminex Assay Kit for Chemerin (CHEM) ,etc. | Magnetic Luminex Assay for Antigen Detection. |
KSA945Mu01 | ELISA Kit DIY Materials for Chemerin (CHEM) | Main materials for "Do It (ELISA Kit) Yourself". |