ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP)

CAP18; FALL39; HSD26; LL37; 18 kDa Cationic Antimicrobial Protein; Antibacterial protein FALL-39; FALL-39 peptide antibiotic

  • ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP) Packages (Simulation)
  • ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP) Packages (Simulation)
  • ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP) Results demonstration
  • CEC419Ra.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP)

This assay has high sensitivity and excellent specificity for detection of Cathelicidin Antimicrobial Peptide (CAMP).
No significant cross-reactivity or interference between Cathelicidin Antimicrobial Peptide (CAMP) and analogues was observed.

Recovery of the ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP)

Matrices listed below were spiked with certain level of recombinant Cathelicidin Antimicrobial Peptide (CAMP) and the recovery rates were calculated by comparing the measured value to the expected amount of Cathelicidin Antimicrobial Peptide (CAMP) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 80-104 89
EDTA plasma(n=5) 79-92 84
heparin plasma(n=5) 79-89 81

Precision of the ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Cathelicidin Antimicrobial Peptide (CAMP) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Cathelicidin Antimicrobial Peptide (CAMP) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Cathelicidin Antimicrobial Peptide (CAMP) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 81-91% 78-90% 91-98%
EDTA plasma(n=5) 80-94% 84-93% 93-101% 87-101%
heparin plasma(n=5) 79-94% 86-102% 83-104% 89-102%

Stability of the ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP)

1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
7. Add 50µL Stop Solution. Read at 450 nm immediately.

Test principle of the ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP)

This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Cathelicidin Antimicrobial Peptide (CAMP) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Cathelicidin Antimicrobial Peptide (CAMP) and unlabeled Cathelicidin Antimicrobial Peptide (CAMP) (Standards or samples) with the pre-coated antibody specific to Cathelicidin Antimicrobial Peptide (CAMP). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Cathelicidin Antimicrobial Peptide (CAMP) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Cathelicidin Antimicrobial Peptide (CAMP) in the sample.

Related products

Catalog No. Organism species: Rattus norvegicus (Rat) Applications (RESEARCH USE ONLY!)
RPC419Ra01 Recombinant Cathelicidin Antimicrobial Peptide (CAMP) Positive Control; Immunogen; SDS-PAGE; WB.
PAC419Ra01 Polyclonal Antibody to Cathelicidin Antimicrobial Peptide (CAMP) WB; IHC; ICC; IP.
SEC419Ra ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP) Enzyme-linked immunosorbent assay for Antigen Detection.
CEC419Ra ELISA Kit for Cathelicidin Antimicrobial Peptide (CAMP) Enzyme-linked immunosorbent assay for Antigen Detection.
LMC419Ra Multiplex Assay Kit for Cathelicidin Antimicrobial Peptide (CAMP) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
KSC419Ra11 ELISA Kit DIY Materials for Cathelicidin Antimicrobial Peptide (CAMP) Main materials for "Do It (ELISA Kit) Yourself".
GUESTBOOK