ELISA Kit for Bridging Integrator 1 (BIN1)

AMPH2; AMPHL; SH3P9; Amphiphysin II; Myc Box-Dependent-Interacting Protein 1; Amphiphysin-like protein

  • ELISA Kit for Bridging Integrator 1 (BIN1) Packages (Simulation)
  • ELISA Kit for Bridging Integrator 1 (BIN1) Packages (Simulation)
  • ELISA Kit for Bridging Integrator 1 (BIN1) Results demonstration
  • SEJ555Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Bridging Integrator 1 (BIN1)

This assay has high sensitivity and excellent specificity for detection of Bridging Integrator 1 (BIN1).
No significant cross-reactivity or interference between Bridging Integrator 1 (BIN1) and analogues was observed.

Recovery of the ELISA Kit for Bridging Integrator 1 (BIN1)

Matrices listed below were spiked with certain level of recombinant Bridging Integrator 1 (BIN1) and the recovery rates were calculated by comparing the measured value to the expected amount of Bridging Integrator 1 (BIN1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 85-104 89
EDTA plasma(n=5) 97-105 102
heparin plasma(n=5) 79-104 92

Precision of the ELISA Kit for Bridging Integrator 1 (BIN1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Bridging Integrator 1 (BIN1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Bridging Integrator 1 (BIN1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Bridging Integrator 1 (BIN1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Bridging Integrator 1 (BIN1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 78-103% 79-104% 83-97%
EDTA plasma(n=5) 83-103% 80-102% 98-105% 89-101%
heparin plasma(n=5) 98-105% 83-104% 84-95% 82-96%

Stability of the ELISA Kit for Bridging Integrator 1 (BIN1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Bridging Integrator 1 (BIN1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Bridging Integrator 1 (BIN1)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Bridging Integrator 1 (BIN1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Bridging Integrator 1 (BIN1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Bridging Integrator 1 (BIN1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Bridging Integrator 1 (BIN1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
URPJ555Hu01 Recombinant Bridging Integrator 1 (BIN1) Positive Control; Immunogen; SDS-PAGE; WB.
UPAJ555Hu01 Polyclonal Antibody to Bridging Integrator 1 (BIN1) WB; IHC; ICC; IP.
UMAJ555Hu21 Monoclonal Antibody to Bridging Integrator 1 (BIN1) WB; IHC; ICC; IP.
USEJ555Hu ELISA Kit for Bridging Integrator 1 (BIN1) Enzyme-linked immunosorbent assay for Antigen Detection.
ULMJ555Hu Multiplex Assay Kit for Bridging Integrator 1 (BIN1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK