ELISA Kit for Adrenomedullin (ADM)

AM; PAMP; Proadrenomedullin N-20 terminal peptide; ProAM N-terminal 20 peptide

  • ELISA Kit for Adrenomedullin (ADM) Packages (Simulation)
  • ELISA Kit for Adrenomedullin (ADM) Packages (Simulation)
  • ELISA Kit for Adrenomedullin (ADM) Results demonstration
  • SEA220Bo.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Adrenomedullin (ADM)

This assay has high sensitivity and excellent specificity for detection of Adrenomedullin (ADM).
No significant cross-reactivity or interference between Adrenomedullin (ADM) and analogues was observed.

Recovery of the ELISA Kit for Adrenomedullin (ADM)

Matrices listed below were spiked with certain level of recombinant Adrenomedullin (ADM) and the recovery rates were calculated by comparing the measured value to the expected amount of Adrenomedullin (ADM) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 96-105 101
EDTA plasma(n=5) 81-99 84
heparin plasma(n=5) 90-104 96

Precision of the ELISA Kit for Adrenomedullin (ADM)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Adrenomedullin (ADM) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Adrenomedullin (ADM) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Adrenomedullin (ADM)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Adrenomedullin (ADM) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 82-95% 94-102% 89-103%
EDTA plasma(n=5) 94-103% 99-105% 87-94% 88-95%
heparin plasma(n=5) 81-105% 89-104% 78-89% 85-94%

Stability of the ELISA Kit for Adrenomedullin (ADM)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Adrenomedullin (ADM)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Adrenomedullin (ADM)

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Adrenomedullin (ADM). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Adrenomedullin (ADM). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Adrenomedullin (ADM), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Adrenomedullin (ADM) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Bos taurus; Bovine (Cattle) Applications (RESEARCH USE ONLY!)
RPA220Bo01 Recombinant Adrenomedullin (ADM) Positive Control; Immunogen; SDS-PAGE; WB.
PAA220Bo01 Polyclonal Antibody to Adrenomedullin (ADM) WB; IHC; ICC; IP.
LAA220Bo71 Biotin-Linked Polyclonal Antibody to Adrenomedullin (ADM) WB; IHC; ICC.
LAA220Bo81 FITC-Linked Polyclonal Antibody to Adrenomedullin (ADM) WB; IHC; ICC; IF.
MAA220Bo21 Monoclonal Antibody to Adrenomedullin (ADM) WB; IHC; ICC; IP.
SEA220Bo ELISA Kit for Adrenomedullin (ADM) Enzyme-linked immunosorbent assay for Antigen Detection.
LMA220Bo Multiplex Assay Kit for Adrenomedullin (ADM) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK