ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11)

DNAHBL; DNAHC11; DNHBL; DPL11; Dynein,Heavy Chain Beta-Like; Axonemal beta dynein heavy chain 11; Ciliary dynein heavy chain 11

  • ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) Packages (Simulation)
  • ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) Packages (Simulation)
  • ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) Results demonstration
  • AEJ201Hu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11)

This assay has high sensitivity and excellent specificity for detection of Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11).
No significant cross-reactivity or interference between Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) and analogues was observed.

Recovery of the ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11)

Matrices listed below were spiked with certain level of Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) and the recovery rates were calculated by comparing the measured value to the expected amount of Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 98-105 101
EDTA plasma(n=5) 90-101 96
heparin plasma(n=5) 86-93 90

Precision of the ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-95% 79-95% 87-94% 99-105%
EDTA plasma(n=5) 78-96% 87-101% 79-102% 85-99%
heparin plasma(n=5) 91-98% 93-101% 80-101% 87-96%

Stability of the ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 5 times;
5. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
6. Add 50µL Stop Solution. Read at 450nm immediately.

Test principle of the ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11)

The microtiter plate provided in this kit has been pre-coated with an antigen. Standards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated secondary antibody. After TMB substrate solution is added, those wells that contain Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Related products

Catalog No. Organism species: Homo sapiens (Human) Applications (RESEARCH USE ONLY!)
RPJ201Hu01 Recombinant Dynein, Axonemal, Heavy Chain 11 (DNAH11) Positive Control; Immunogen; SDS-PAGE; WB.
RPJ201Hu02 Recombinant Dynein, Axonemal, Heavy Chain 11 (DNAH11) Positive Control; Immunogen; SDS-PAGE; WB.
PAJ201Hu01 Polyclonal Antibody to Dynein, Axonemal, Heavy Chain 11 (DNAH11) WB; IHC; ICC; IP.
PAJ201Hu02 Polyclonal Antibody to Dynein, Axonemal, Heavy Chain 11 (DNAH11) WB; IHC; ICC; IP.
MAJ201Hu23 Monoclonal Antibody to Dynein, Axonemal, Heavy Chain 11 (DNAH11) WB; IHC; ICC; IP.
MAJ201Hu24 Monoclonal Antibody to Dynein, Axonemal, Heavy Chain 11 (DNAH11) WB; IHC; ICC; IP.
MAJ201Hu25 Monoclonal Antibody to Dynein, Axonemal, Heavy Chain 11 (DNAH11) WB; IHC; ICC; IP.
MAJ201Hu22 Monoclonal Antibody to Dynein, Axonemal, Heavy Chain 11 (DNAH11) WB; IHC; ICC; IP.
MAJ201Hu21 Monoclonal Antibody to Dynein, Axonemal, Heavy Chain 11 (DNAH11) WB,IHC
SEJ201Hu ELISA Kit for Dynein, Axonemal, Heavy Chain 11 (DNAH11) Enzyme-linked immunosorbent assay for Antigen Detection.
AEJ201Hu ELISA Kit for Anti-Dynein, Axonemal, Heavy Chain 11 Antibody (Anti-DNAH11) Enzyme-linked immunosorbent assay for Antibody Detection.
LMJ201Hu Multiplex Assay Kit for Dynein, Axonemal, Heavy Chain 11 (DNAH11) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK