ELISA Kit for Activin A Receptor Type I C (ACVR1C)
ACVR1-C; ALK7; ACVRLK7; Activin receptor-like kinase 7
- Product No.SEC116Hu
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range0.312-20ng/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.117ng/mL.
- Sample Typetissue homogenates, cell lysates, cell culture supernates and other biological fluids
- Download Instruction Manual
- UOM 48T96T 96T*5 96T*10 96T*100
-
FOB
US$ 490
For more details, please contact local distributors!US$ 700
For more details, please contact local distributors! US$ 3150
For more details, please contact local distributors! US$ 5950
For more details, please contact local distributors! US$ 49000
For more details, please contact local distributors!
Specificity of the ELISA Kit for Activin A Receptor Type I C (ACVR1C)
This assay has high sensitivity and excellent specificity for detection of Activin A Receptor Type I C (ACVR1C).
No significant cross-reactivity or interference between Activin A Receptor Type I C (ACVR1C) and analogues was observed.
Precision of the ELISA Kit for Activin A Receptor Type I C (ACVR1C)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Activin A Receptor Type I C (ACVR1C) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Activin A Receptor Type I C (ACVR1C) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Stability of the ELISA Kit for Activin A Receptor Type I C (ACVR1C)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the ELISA Kit for Activin A Receptor Type I C (ACVR1C)
1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the ELISA Kit for Activin A Receptor Type I C (ACVR1C)
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Activin A Receptor Type I C (ACVR1C). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Activin A Receptor Type I C (ACVR1C). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Activin A Receptor Type I C (ACVR1C), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Activin A Receptor Type I C (ACVR1C) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
INCREMENT SERVICES
Single-component Reagents of Assay Kit
Lysis Buffer Specific for ELISA / CLIA
Quality Control of Kit
ELISA Kit Customized Service
Disease Model Customized Service
Serums Customized Service
TGFB1 Activation Reagent
Real Time PCR Experimental Service
Streptavidin
Fast blue Protein Stain solution
Single-component Reagents of FLIA Kit
Streptavidin-Agarose Beads
Related products
Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
RPC116Hu01 | Recombinant Activin A Receptor Type I C (ACVR1C) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAC116Hu01 | Polyclonal Antibody to Activin A Receptor Type I C (ACVR1C) | WB; IHC; ICC; IP. |
SEC116Hu | ELISA Kit for Activin A Receptor Type I C (ACVR1C) | Enzyme-linked immunosorbent assay for Antigen Detection. |