CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1)

EPO; CLGI; EPA; HCI; Erythroid Potentiating Activity; Collagenase Inhibitor; Metalloproteinase inhibitor 1; Fibroblast collagenase inhibitor

  • CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) Packages (Simulation)
  • CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) Packages (Simulation)
  • CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) Results demonstration
  • SCA552Mu.jpg Typical Standard Curve
  • Certificate ISO9001: 2008, ISO13485: 2003 Registered

Specificity of the CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1)

This assay has high sensitivity and excellent specificity for detection of Tissue Inhibitors Of Metalloproteinase 1 (TIMP1).
No significant cross-reactivity or interference between Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) and analogues was observed.

Recovery of the CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1)

Matrices listed below were spiked with certain level of recombinant Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) and the recovery rates were calculated by comparing the measured value to the expected amount of Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 83-101 93
EDTA plasma(n=5) 86-101 97
heparin plasma(n=5) 89-96 92

Precision of the CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1)

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity of the CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1)

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 81-88% 92-102% 87-94% 80-90%
EDTA plasma(n=5) 99-105% 96-104% 78-92% 83-93%
heparin plasma(n=5) 83-95% 97-104% 92-99% 84-94%

Stability of the CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1)

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Assay procedure summary of the CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1)

1. Prepare all reagents, samples and standards;
2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;
3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
8. Read RLU value immediately.

Test principle of the CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1)

The microplate provided in this kit has been pre-coated with an antibody specific to Tissue Inhibitors Of Metalloproteinase 1 (TIMP1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Tissue Inhibitors Of Metalloproteinase 1 (TIMP1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) level in the sample or standard.;

Related products

Catalog No. Organism species: Mus musculus (Mouse) Applications (RESEARCH USE ONLY!)
RPA552Mu02 Recombinant Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) Positive Control; Immunogen; SDS-PAGE; WB.
RPA552Mu01 Recombinant Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) Positive Control; Immunogen; SDS-PAGE; WB.
PAA552Mu01 Polyclonal Antibody to Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) WB; IHC; ICC; IP.
PAA552Mu02 Polyclonal Antibody to Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) WB; IHC; ICC; IP.
LAA552Mu71 Biotin-Linked Polyclonal Antibody to Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) WB; IHC; ICC.
SEA552Mu ELISA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) Enzyme-linked immunosorbent assay for Antigen Detection.
SCA552Mu CLIA Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) Chemiluminescent immunoassay for Antigen Detection.
LMA552Mu Multiplex Assay Kit for Tissue Inhibitors Of Metalloproteinase 1 (TIMP1) ,etc. by FLIA (Flow Luminescence Immunoassay) FLIA Kit for Antigen Detection.
GUESTBOOK